background image

3-1

ML-705M Series Electro-Mechanical Lock

Copyright © All Rights Reserved.  P-MU-ML-705  Published: 2020.12.07

Unit: mm

Installation Instruction

Dimension

Specification

Packing Contents

Stud Bolt Position

Lock Bolt

Nib

Strike Plate

Australian profile 

key cylinder hole

Caution:

Do not completely remove screw 2 (as marked in the figure) 

as the interior solenoid might fall off.

Version Changeable:

Take out the Screw 1 , release screw 2 , move the 

position and then tighten both screws.

“Fail-Safe” 

(Power to Lock)

“Fail-Secure” 

(Power to Open)

For fail-safe mode

For fail-secure mode

Operating Voltage: 12~24VDC/AC ±10% 
Current Draw: 250mA/12VDC; 150mA/24VDC
Operating Temperature: 14°F to 120°F (-10°C~+49°C)
Humidity: 0~85% non-condensing
Version Changeable: Fail-safe or Fail-secure
Lock bolt sensor switch output: SPDT, 3A/125VAC
Latch Throw:16mm
Solenoid testing: Tested to 250,000 cycles
Resistance against door being forced :
1500 lbs (static force); 70 ft-lbs (dynamic force)
Backset: 25mm

25

Backset

21

230

82

49

160.5

250

275

28

100

125

150

2

2

1

2

1

2

1

2

1

2

1

2

1