background image

Anybus Communicator - PROFINET IRT (2.32) Interface

Installation Guide

www.anybus.com

SP2193 1.01  Dec 2016

Front View

Bottom View

1

4

1
2

1

5

6

9

PC Connector

1. GND
2. GND
3. RS232 

Rx

4. RS232 

Tx

Subnetwork Connector

1. +5V 

OUT

2. RS-232 

Rx

3. RS-232 

Tx

4. NC
5. Signal 

GND

6. RS-422 

Rx+

7. RS-422 

Rx-

8. RS-485+/RS-422 

Tx+

9. RS-485-/RS-422 

Tx- 

Power Connector

1. 

+24 V DC

2. GND

Accessories Checklist

The following items are required for installation:

• Anybus 

Con

fi

 guration Manager - Communicator RS-232/422/485 

(available at 

www.anybus.com

)

• RS-232 

con

fi

 guration cable

• Subnetwork 

connector

• 

PROFINET network cable and connector (not included)

Installation and Startup Summary

1. 

Mount the gateway on the DIN rail

2. 

Connect the gateway to the PROFINET network

3. 

Connect the gateway to the subnetwork

4. 

Power on the gateway

5. 

Connect the con

fi

 guration cable between the gateway and 

the PC containing Anybus Con

fi

 guration Manager

6. Con

fi

 gure the gateway using Anybus Con

fi

 guration Manager

7. Con

fi

 gure and start the PROFINET network

LED Indicators

LED

Indication

Meaning

1 (Network Status)

Off

Of

fl

 ine

- No power

- No connection with IO Controller

Green

Online (RUN)

- Connection with IO Controller established

Green, 1 

fl

 ash

Online (STOP)

- Connection with IO Controller established

- IO Controller in STOP state or IO data bad

- RT synchronization not 

fi

 nished

Green, blinking

Node identi

fi

 cation (see manual)

Red

Fatal error

Red, 1 

fl

 ash

Station name error

Red, 2 

fl

 ashes

IP address error

Red, 3 

fl

 ashes

Con

fi

 guration error

Alternating Red/Green

Firmware update in progress

2 (Module Status)

Off

No power or initializing

Green

Normal operation

Green, 1 

fl

 ash

Diagnostic event present

Red

Fatal error

Alternating Red/Green

Firmware update in progress

3/4 (Link Activity)

Green

Link OK

Green, 

fl

 ickering

Transmitting/receiving data

Off

Link not detected or no power

5 (Subnet Status)

Green, 

fl

 ashing

Running, one or more transaction errors

Green

Running

Red

Transaction error/timeout or subnet stopped

6 (Device Status)

Off

No power

Green

Initializing

Green, 

fl

 ashing

Running

Red

Bootloader mode

Alternating red/green

Con

fi

 guration error

1
3

5

2
4
6

Network Status

Device Status

Subnet Status

LAN Port 1

LED Indicators

Link Activity 1

Module Status

Link Activity 2

LAN Port 2

LAN Connector (RJ-45)

1. TD+
2. TD-
3. RD+
4. (reserved)
5. (reserved)
6. RD-
7. (reserved)
8. (reserved)

1

8

Reviews: