ASP-8/10/12/15KTLC
24
distance between inverter and
grid connecting point more than
80m. When there are multiple
inverters in project, it can firstly
use combiner box to combine
outputs of inverters, then choose
cable with bigger diameter.
ASP-10KTLC
10
10
10
ASP-12KTLC
10
10
16
ASP-15KTLC
10
10
16
ATTENTION
1. Inverter’s terminals except its AC side are plug-in type.
2.
Cables on AC side are better to be flexible copper cable.
DC Wiring
Note:
Ensure DC switch is off before connecting with PV arrays.
Ensure PV array’s polarity match with inverter DC connectors.
Ensure each PV string voltage won't exceed 1000V.
DC connector must be provided by AOTAI.
It is forbidden to connect PE wire (ground wire) to positive and negative poles
of PV arrays, otherwise it will cause inverter damage.
Step1: Remove insulation layer of 7-8mm from all DC cables.