ASP-8/10/12/15KTLC
31
6. Operating guide
6.1 Working modes
Inverter working modes include:
“Start-up
”, “
Running
”, “
Stand-by
”, “
Fault
”
and “
Stop
”. LCD shows corresponding info in each working mode.
ATTENTION
The data in the Figure and Table is just for reference. Take ASP
-10KTLC for example.
Start-up
Start-up mode means inverter is preparing to generate power, but not yet. In this
mode, inverter tests whether PV array meets needs of on-grid generating capacity
condition continuously, if yes, inverter will change to
Running
mode from
Start-up
mode. Sequence of displayed messages is shown in Table 6-1, take
ASP-10KTLC for example.
Table 6-1:Display sequence in “Startup” mode
ATTENTION
When PV array voltage >300V, start-up timer begins its
countdown for 20s. If PV array voltage meets requirement of
grid connecting power generation within 20s, Running mode
will start.
Sequence
Displayed info
Time of
duration(S)
Remark
1
Thanks For Using
Address 1
10
2
Reconnecting in
20 seconds
20