background image

G Series

    Quick Start Guide

 

 

 

9

 

3.1.4. View History Route 

 

Summary of Contents for G Series

Page 1: ...WE TRACK AND PROTECT YOUR ASSETS Assets Tracker Quick Start Guide G Series V1 1 www aovx com ...

Page 2: ...torage Loss Alarm 3 1 6 Low Power Alarm 3 1 7 Electronic Fence 3 1 8 OTA Upgrade 3 2 Parameter Configuration 4 3 Platform Management 7 3 1 AOVX Cloud Platform 7 3 2 Third Party or Customer Owned Platform 11 4 FAQ 12 4 1 Vibration Alarm Test 12 4 2 Temperature and Humidity Alarm 13 4 3Tamper Alert 13 4 4 Position Unfixed or Huge Deviation 14 4 5 Unable to Register 14 ...

Page 3: ...he switch to the OFF position and insert the Micro SIM card If your SIM card requires configuring the APN please confirm the APN info with the card issuing operator And refer to Chapter 2 to configure 1 1 4 Installation Location Place it directly in the product packaging box after opening the device or stick the adhesive on the outside of the goods packaging box Be sure the logo faces down light s...

Page 4: ...re and humidity information every 10 minutes and store it locally then report to the platform every hour When the GNSS positioning fails the base station or WiFi positioning will be activated as assistance If the device does not detect the network it will stop reporting and enters sleep mode After reconnecting to the network it will relocate and report Triggered reporting when the device detects a...

Page 5: ...vement status and generate a report if it s static for too long Triggered reporting when the device detects the violent vibration of assets it will trigger an alarm to the platform 1 5 Local Storage Loss Alarm When the device is detected that the local SD TF card is removed or damaged an alarm message will be triggered 1 6 Low Power Alarm If the device is of low power supply the platform will trig...

Page 6: ...nfiguration tool and connect the device If you need to configure the APN please confirm the APN with the card issuing operator Follow the steps below to set it up 1 Please connect the device to the computer via a USB cable 2 Choose correct serial port and device type ...

Page 7: ... shown is display area and filled in parameter area 5 Find the parameter you want to change input value or choose status then click on the box on the right 6 Click on Config button to set the value 7 Local CFG Succeed means configuration is done You can query parameter again to double check ...

Page 8: ...G Series Quick Start Guide 6 ...

Page 9: ...me and password are provided by AOVX administrator 3 1 1 Add Goods Enter Goods Management Goods List Add Goods Fill in requested information so it ll be easy to search your assets or goods Be noted IMEI must be the same with the label sticked to the back side of the device Departure time means you want to view the status information of the device from which point in time the arrival time can be es...

Page 10: ...l on the back of the device Only by adding goods and device at the same time they can be bound correctly then the route will be correctly displayed 3 1 3 Check Status After device is correctly added in platform you can click the corresponding Details in the Good List to open the track location data list and line chart of the goods ...

Page 11: ...G Series Quick Start Guide 9 3 1 4 View History Route ...

Page 12: ...G Series Quick Start Guide 10 3 1 5 View Current Position 3 1 6 Check Temperature and Humidity Information ...

Page 13: ...G Series Quick Start Guide 11 3 2 Third Party or Customer Owned Platform Please refer to the device interface protocol AOVX_Assets Tracker_G_Series_Cloud Platform Protocol ...

Page 14: ...Start Guide 12 4 FAQ 4 1 Vibration Alarm Test Hold the device and shake it back and forth quickly When the motion count exceeds the preset value an alarm will be triggered You can check the platform to view the alarm ...

Page 15: ...vironment as required by the test As long as the ambient temperature and humidity exceeds the set threshold the high temperature and humidity alarm will be triggered 4 3Tamper Alert Cover up the light sensor first then remove coverings Tamper alert will be triggered immediately when light intensity exceeds the value we set ...

Page 16: ...lution2 Put the device correctly or change to another position Make sure no insulation film on the glass 4 5 Unable to Register Question1 The SIM card is not installed properly or loose there is dirt on the metal surface of the SIM card the SIM card is damaged or invalid Solution1 Check SIM card and reinstall please wipe it with a clean cloth replace the valid SIM card Question2 Beyond the operato...

Page 17: ...WE TRACK AND PROTECT YOUR ASSETS AOVX Assets Tracker Solutions Corp Website www aovx com Mail info aovx com Tel 86 18949864976 ...

Reviews: