28
PROBLEM 1: THE UNIT HAS NO POWER
1. Check if the unit is switched ON.
2. Check the fuse. Replace with the same type if fuse is blown.
3. Check the power cord and make sure there are no disconnections.
4. Verify that the unit is properly connected to the power source.
PROBLEM 2: HOTAIR GUN TEMPERATURE DISPLAY IS ALWAYS
ABOVE 500
o
C
Description:
Constant display of above 500
o
C temperature from the panel
then displays an “Err1” on the panel after a few minutes.
SOLUTION:
The thermal sensor may be broken and needs to be replaced.
PROBLEM 3: HOTAIR GUN ACTUAL AIR TEMPERATURE IS NOT IN
CREASING
Description:
Actual temperature reading is not increasing or decreasing
based on desired level.
SOLUTION:
The heating element may be broken or is at the end of its life and needs to
be replaced.
PROBLEM 4: NO AIR IS COMING OUT OF THE HOT AIR GUN
Description:
No air is flowing out of the nozzle, the nozzle heats up, and no
sound can be heard on the air intake end of the hand piece.
SOLUTION:
The fan may be broken and needs to be replaced. See replacing the Fan on
page 27.
BASIC TROUBLESHOOTING GUIDE
5
PACKAGE INCLUSION
Hot Air Gun
Air Nozzles
(1010, 1194, 1195)
Power Cord
939 Vacuum
Suction Pen
G001 IC Popper
2630B Soldering Iron Holder
with Solder Wire Stand
Hot Air Gun Holder
PART NO.
DESCRIPTION
10094
Hot air gun heating element
30106S
Plastic handle of hot air gun
S009
Hot air gun complete handle
20962
Hot air gun metal pipe
P002
Diaphragm pump
30127S
Soldering Iron plastic handle
B011
Soldering Iron complete handle
SPARE PARTS GUIDE
6031 Main Station
LF2B Tip
30150J
Heat Resistant Pad