To Remove SMD ICs: 

1. 

Plug the power cord into the power supply. 

2. 

Turn the power switch on. 

3. 

Display will show the current temperature, pressing the up and down 
temperature settings button will switch the display to the set tempera-
ture, after a few seconds it would revert back to displaying the  actual 
temperature. 

4. 

When the airflow is adjusted the display will show the set air flow , it 
would revert back to the actual temperature after a few seconds. 

5. 

Adjust the air flow and temperature , wait for the temperature to sta-
bilize for 30 to 60 seconds. 

6. 

For  your  reference,  we  recommend  you  to  adjust  the  temperature 
around  300  to  350

℃ 

(For  8032  see  reference  figure  ),  and  an  air 

pressure of around 15—30 (For 8032 set to 1-3 ). 

7. 

Hold the  unit so that the nozzle is located over the IC.  Move around 
the leads of the IC until the solder melts. 

8. 

Pick up the IC using a vacuum pick up pen or tweezers 

9. 

Allow ICs and PCB to cool down. 

 

To Solder SMD ICs: 

1. 

Apply  solder paste to the  PCB. 

2. 

Carefully  place  the  IC  on  the  PCB,  use    tweezers  to  properly  align 
the legs of the IC to leads at the PCB . 

3. 

Preheat PCB and IC together, use a pre-heater for best results .  

4. 

Wait for the PCB temperature to reach 180 degrees Celsius. 

5. 

Turn on the unit and set the air pressure to  15(For 8032 set to 1-3 ). 

6. 

Set hot-air temperature to 350. 

7. 

Position the nozzle on top of the IC leads, Heat IC’s  leads evenly. 

8. 

Wait  for  the  solder  paste  to  be  activated  and  meld  the  IC  with  the 
PCB. 

 

OPERATING GUIDELINES 

7

 

Summary of Contents for 8032

Page 1: ...to heat targeted areas evenly and effectively Thank you for purchasing Aoyue 8032 8032A Hand held hot air gun It is important to read the manual before using the equipment Please keep manual in accessible place for future reference INSTRUCTION MANUAL HAND HELD HOT AIR GUN ...

Page 2: ......

Page 3: ...ons 3 Functions and features 4 Replacement heating elements 4 Safety Precaution 5 Panel Guide 6 Operation Guidelines Removing SMD 7 Soldering SMD 7 After usage 8 Replacing the heating element 8 Temperature Chart 9 Air Nozzles 10 2 ...

Page 4: ...wer Input available in 110V 220V Dimensions 65 w x 252 L mm Max Power Consumption 550W Temperature Range 100 C 480 C Heating Element Metal Heating Core Fan Type Turbine Motor Air Capacity 35 l min max SPECIFICATIONS 3 ...

Page 5: ...devices Specially applicable for reworking mobile phone ICs BGA SMD and other electronic parts Designed to be handy and small which saves up valuable work space environment Electro Static safe design to prevent damaging sensitive ICs PCB from static and leak electricity Over heat protection heating element auto shuts off when tem perature rises over the maximum limit to protect the system and its ...

Page 6: ...rounded receptacle Caution High Temperature Operation After use be sure to cool the unit Do not disassemble the unit Disconnect the plug when unit is not in use for a long time When the power cord is connected into the power supply the unit has a little flow of electricity even if the power switch is in off position Do not use the unit near ignitable gases paper or other inflammable materials both...

Page 7: ...E 8032 8032A Temperature Adjustment Knob Temperature and Airflow display AIR HEATER Air flow Adjustment knob Status LED AIR HEATER RESET Temperature Adjustment Buttons Air flow Ad justment buttons Reset Button 6 ...

Page 8: ...r 8032 see reference figure and an air pressure of around 15 30 For 8032 set to 1 3 7 Hold the unit so that the nozzle is located over the IC Move around the leads of the IC until the solder melts 8 Pick up the IC using a vacuum pick up pen or tweezers 9 Allow ICs and PCB to cool down To Solder SMD ICs 1 Apply solder paste to the PCB 2 Carefully place the IC on the PCB use tweezers to properly ali...

Page 9: ...e out the nozzle 3 Detach heating element from its socket 4 Place the new heating element to the socket Caution Handle heating elements with care Never rub the heating element s wire 5 Assemble the Handle in the reverse order of disassembly 6 Check all connections properly Note For 8032A the heating element s thermal sensor are the red and blue wires The two wires should have the same position ar ...

Page 10: ...ure settings level 4 Temperature settings level 5 For 1197 type nozzle 0 200 400 600 3 4 5 6 Air Flow Level Settings Temperature in Degrees Celcius Temperature setting level 3 Temperature setting level 4 Temperature setting level 5 For 1313 type nozzle 0 200 400 600 3 4 5 6 Air Flow Level Settings Temperature in Degrees Celcius Temperature setting level 3 Temperature setting level 4 Temperature se...

Page 11: ...1 3 8 9 10 3 1132 5 6 13mm 16 4 7 14 11 7 1133 7 5 15mm 17 6 15 13 1134 7 5 18mm 20 6 18 13 1257 11 21mm 22 11 20 18 1258 7 6 12 7mm 12 7 10 14 1259 13 28mm 30 12 5 28 19 5 1260 8 6 18mm 20 7 7 18 14 7 MODEL IC SIZE L mm W mm A mm B mm 1183 15 8mm 17 7 15 14 1184 18 8mm 20 9 18 16 1214 10 26mm 27 11 25 18 TSOL SERIES MODEL IC SIZE L mm W mm A mm B mm 1185 13 10mm 11 11 9 18 1186 18 10mm 12 17 10 2...

Page 12: ...ll also available in an alternative format e g on a website A fire may result if the appliance is not used with care therefore be careful when using the appliance in places where there are combustible materials do not apply to the same place for a long time do not use in presence of an explosive atmosphere be aware that heat may be conducted to combustible materials that are out of sight place the...

Reviews: