background image

14  

BASIC TROUBLESHOOTING GUIDE 

PROBLEM 1: THE UNIT HAS NO POWER 
1. 

Check if the unit is switched ON. 

2. 

Check the fuse. Replace with the same type if fuse is blown. 

3. 

Check the power cord and make sure there are no disconnections. 

4. 

Verify that the unit is properly connected to the power source. 

 
PROBLEM 2: HOT-AIR GUN TEMPERATURE DISPLAY IS ALWAYS ABOVE 500

o

Description:  Constant display of above 500

o

C temperature

 

from the panel then displays an  

“OFF” on  the panel after a few minutes. 
 
SOLUTION:  
The thermal sensor may be broken and needs to be replaced. 
 
PROBLEM 3: HOT-AIR GUN ACTUAL AIR TEMPERATURE IS NOT INCREASING 
Description: Actual temperature reading is not increasing based on desired level. 
SOLUTION: 
The heating element may be broken or is at the end of its life and needs to be replaced. 
 
PROBLEM 4: THE UNIT IS VIBRATING TOO MUCH 
SOLUTION:  
Check if the pump is properly secured. Unplug the system from the main power 
source before opening the case to check inside the station. 
 
PROBLEM 5: THE UNIT IS VERY NOISY 
SOLUTION:  
Make sure the screw at the center of the base of the main unit has been removed. This holds 
the pump in place during transportation and needs to be removed before using the equipment. 
 
PROBLEM 6: UNIT SHOWS UNCONVENTIONAL BEHAVIOR 
Description: 
Unit operates erratically.  
SOLUTION: Try to switch OFF the device and switch ON again.  
 
OTHER PROBLEMS NOT MENTIONED: 
Contact the vendor. 
  
 
 
 

 3 

 

The Aoyue int 852A+ pro/ int 852A++ pro SMD Rework is a 

reworking tool designed to remove and/or repair surface mounted 
devices such as SOIC, CHIP, QFP, BLCC, BGA, and so on.  
 

It has several safety features such as the auto-cooling process of 

the Hot Air Gun. This functionality protects the device (and its 
components) from excessive heat upon reaching any of the following  
conditions: (1) when the soldering gun remained idle on its resting 
handle after a certain period and (2) when the temperature of the 
device is above a safe threshold upon turning off. 

 

PRODUCT DESCRIPTION  

 
 

SPECIFICATION 

Specifications are subject to change without prior notice. 

 Station Dimensions 

188 (W) x 127 (L) x 244 (D) mm 

 Weight 

3.8 Kg. 

 Power Input 

AC 110-220 V / 50-60 Hz 

 Power Consumption 

500 W 

 Temperature Range 

100°C - 480°C 

 Heating Element Type 

Metal Heating Core 

 Pump/Motor Type 

Diaphragm Special-Purpose Lathe Pump 

 Air Capacity 

23 l/min (Max) 

Summary of Contents for Int 852A++ pro

Page 1: ...ttp www aoyue com SMD Rework Station INSTRUCTION MANUAL Thank you for purchasing Aoyue int 852A pro int 852A pro SMD Rework Station It is important to read the manual before using the equipment Please...

Page 2: ...shooting Guide 14 Air Nozzles 15 This manual is designed to familiarize and instruct the op erator with the proper usage and maintenance of the equipment The Care and Safety Precautions section explai...

Page 3: ...enter of the base of the main unit has been removed This holds the pump in place during transportation and needs to be removed before using the equipment PROBLEM 6 UNIT SHOWS UNCONVENTIONAL BEHAVIOR D...

Page 4: ...needed the following procedure can be done 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to SEL 4 then press the air flow control up button C3 2 If successful the display B2 w...

Page 5: ...y please observe the ff precautions Check each component after opening the package to make sure everything is in good condition If there are any suspected damage do not use the item and report the iss...

Page 6: ...t 60 indicating soldering iron sleep timer setting is being set 4 Adjust the sleep timer with the air flow control buttons C3 and C4 Sleep timer is adjustable from 5 to 60 minutes with t OFF signifyin...

Page 7: ...ing the procedures below 1 Turn off unit 2 Ensure that the Hot Air gun function switch F is in the ON position 3 Power ON unit by switching the power switch to ON 4 While the AOYUE name is scrolling s...

Page 8: ...the air flow level using the airflow control buttons C3 and C4 from the control panel 5 Adjust the hot air gun air temperature using the temperature control buttons C1 and C2 from the control panel T...

Reviews:

Related manuals for Int 852A++ pro