background image

12  

8. 

To wake the hot air gun from its sleep mode, simply lift the 
hot air gun from it’s holder or press any control button.  

 

Hot air gun proper placement

 

To ensure sleep mode activation handle should be properly placed 
and locked into position. 

 
 

 
 

 

 
 
 
 
F.  Selecting the Temperature Scale
 
  The displayed temperature can be toggled between the 
Centigrade scale or the Fahrenheit scale. 
To switch between the two scales follow these procedures: 

1. Follow System Setting   procedures  1  to  6.  Adjust  system 

selection menu to “SEL 3”, then press the air flow control up 
button  “C3”. 

2.  If successful the display  would show “Set F ” indicating system 

scale setting is being set. 

3.  Select the system temperature scale with the air flow control  

buttons  “C3 and C4”.Select “C” for Celsius scale and select “F” 
for Fahrenheit scale. 

4.  Save the selected temperature scale settings and exit from the 

temperature scale adjustment menu by pressing the Hot Air gun 
function switch “F” . 

OPERATING GUIDELINES 

LOCKED 

Place handle on 

top of cradle 

Pull handle downwards 

to secure in place. 

Handle locked in 

position 

 5 

SAFETY PRECAUTIONS 

CAUTION: 

Improper usage can cause serious injury to personnel  

and/or damage to equipment. For your own safety, please observe  
the ff. precautions.

 

● 

Check each component after opening the package to make sure 
everything is in good condition. If there are any suspected damage, 
do not use the item and report the issue to your vendor. 

● 

Turn OFF the main power switch and unplug the device when 
moving the device from one location to another. 

● 

Do not strike or subject the main unit to physical shock. Use 
carefully to avoid injury and damage to any part. 

● 

Handle with care. 

     - Never drop or sharply jolt the unit. 
     - Contains delicate parts that may break if the unit is dropped. 

● 

Make sure the equipment is always grounded. Always connect 
power to a grounded receptacle. 

● 

Temperature may reach as high as 480°C when switched ON. 
- Do not use the device near flammable gases, paper and other 
flammable materials. 
- Do not touch heated parts, which can cause severe burns. 
- Do not touch metallic parts near the tip. 

● 

Disconnect the plug from the power source if the unit will not be 
used for a long period. 

 

  - Turn off power during breaks, if possible. 

● 

Use only genuine replacement parts. 

 

  - Turn off power and let the unit cool before replacing parts. 

● 

The unit may produce a small amount of smoke and unusual odor 
during initial usage. This is normal and should not yield any 
negative result when reworking. 

● 

Soldering process produces smoke — use on well ventilated place. 

● 

Do not alter the unit, specifically the internal circuitry, in any 
manner. 

 

Summary of Contents for Int 852A++ pro

Page 1: ...ttp www aoyue com SMD Rework Station INSTRUCTION MANUAL Thank you for purchasing Aoyue int 852A pro int 852A pro SMD Rework Station It is important to read the manual before using the equipment Please...

Page 2: ...shooting Guide 14 Air Nozzles 15 This manual is designed to familiarize and instruct the op erator with the proper usage and maintenance of the equipment The Care and Safety Precautions section explai...

Page 3: ...enter of the base of the main unit has been removed This holds the pump in place during transportation and needs to be removed before using the equipment PROBLEM 6 UNIT SHOWS UNCONVENTIONAL BEHAVIOR D...

Page 4: ...needed the following procedure can be done 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to SEL 4 then press the air flow control up button C3 2 If successful the display B2 w...

Page 5: ...y please observe the ff precautions Check each component after opening the package to make sure everything is in good condition If there are any suspected damage do not use the item and report the iss...

Page 6: ...t 60 indicating soldering iron sleep timer setting is being set 4 Adjust the sleep timer with the air flow control buttons C3 and C4 Sleep timer is adjustable from 5 to 60 minutes with t OFF signifyin...

Page 7: ...ing the procedures below 1 Turn off unit 2 Ensure that the Hot Air gun function switch F is in the ON position 3 Power ON unit by switching the power switch to ON 4 While the AOYUE name is scrolling s...

Page 8: ...the air flow level using the airflow control buttons C3 and C4 from the control panel 5 Adjust the hot air gun air temperature using the temperature control buttons C1 and C2 from the control panel T...

Reviews: