background image

6  

CONTROL PANEL GUIDE 

LEGEND: 
B1 -  Temperature Display 
B2  - 

Airflow Level Display 

C1  - 

Temperature Control (Up) 

C2  - 

Temperature Control (Down) 

C3  - 

Airflow Control (Up) 

C4  - 

Airflow Control (Down) 

Hot Air Gun Function Switch 

G -  Airflow 

Gauge 

H  - 

Vacuum pen  

  Connector 
  (for 

i852A++ 

only) 

 

 

B1 

B2 

C1 

Main Power Switch 

Back Panel 

AC Power Inlet with 
Fuse 

C2 

C3  C4 

 11 

OPERATING GUIDELINES 

   Selection Menu 

Function 

Hot Air Gun Sleep Timer 

2 Temperature 

Scale 

Adjustment 

AC Line Frequency Selection 

Hot Air Gun Digital Offset 

E.  Activating Hot Air Gun  Auto-Sleep Mode 
 

The hot air gun’s SLEEP mode can be activated by following the 

set of procedures below: 

1. Follow System Settings  procedures 1 to 6. 
2.  Adjust system selection menu to SEL 1, then press the air flow 

control up button  “C3”. 

3. If successful the display “B1 and B2” would show “t 60” 

indicating soldering iron sleep timer setting is being set. 

4.  Adjust the sleep timer with the air flow control buttons “C3 and 

C4”, Sleep timer is adjustable from 5 to 60 minutes with “t OFF” 
signifying sleep timer is turned off. 

5.  Save the selected timer settings and exit from the sleep timer 

adjustment menu by pressing the Hot Air gun function switch 
“F” . 

6.  If the sleep mode is activated the sleep timer will start counting 

down once the hot air gun is placed securely on the hot air gun  
holder. See: Hot air gun proper placement on page 12. The 
display “B1” will show the letter “L”  indicating the hot air gun 
has been locked into position. 

7.  When the sleep timer expires, the system will start cooling down 

the hot air gun by blowing air at maximum intensity while the 
display shows a flashing OFF to signify hot air gun is currently 
preparing to go into sleep mode. Once the hot air gun actual 
temperature goes below 90 degrees, the display “B1 and B2” 
would show “ - - - -   - - -“ seven dashes indicating hot air gun is 
now in sleep mode. 

Summary of Contents for Int 852A++ pro

Page 1: ...ttp www aoyue com SMD Rework Station INSTRUCTION MANUAL Thank you for purchasing Aoyue int 852A pro int 852A pro SMD Rework Station It is important to read the manual before using the equipment Please...

Page 2: ...shooting Guide 14 Air Nozzles 15 This manual is designed to familiarize and instruct the op erator with the proper usage and maintenance of the equipment The Care and Safety Precautions section explai...

Page 3: ...enter of the base of the main unit has been removed This holds the pump in place during transportation and needs to be removed before using the equipment PROBLEM 6 UNIT SHOWS UNCONVENTIONAL BEHAVIOR D...

Page 4: ...needed the following procedure can be done 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to SEL 4 then press the air flow control up button C3 2 If successful the display B2 w...

Page 5: ...y please observe the ff precautions Check each component after opening the package to make sure everything is in good condition If there are any suspected damage do not use the item and report the iss...

Page 6: ...t 60 indicating soldering iron sleep timer setting is being set 4 Adjust the sleep timer with the air flow control buttons C3 and C4 Sleep timer is adjustable from 5 to 60 minutes with t OFF signifyin...

Page 7: ...ing the procedures below 1 Turn off unit 2 Ensure that the Hot Air gun function switch F is in the ON position 3 Power ON unit by switching the power switch to ON 4 While the AOYUE name is scrolling s...

Page 8: ...the air flow level using the airflow control buttons C3 and C4 from the control panel 5 Adjust the hot air gun air temperature using the temperature control buttons C1 and C2 from the control panel T...

Reviews:

Related manuals for Int 852A++ pro