background image

WARNING: 

When  turned  ON,  temperature  of  the  hot  air  gun  ranges 

from  100°C  ­  480°C.  Injury  might  occur  if  not  handled  properly.

 

Rewor k ing 

OPERATING INSTRUCTIONS 

1.  Plug the power cord. 

2.  Turn on the upper right hand switch.  Digital readout 

of current temperature will appear. 

3.  Adjust

 temperature

 and

 airflow

 according to the type 

of component being reworked. 

4.  When proper adjustment of airflow and temperature 

has been  set, wait a few seconds for the temperature and 

airflow to stabilize. 

5.    Maintain a  15mm  distance  between  the  component 

to be soldered and the hot air gun. 

6.    Move  the  air  gun  in  a  rotating  manner  focusing 

around the component. 

7.   Wait until the component bonds.

 

NOTE: 

If reworking plastic or larger components, 

higher temperature and airflow is needed.

 

CAUTION!  Do  not  let  the  air  stand  in 

one position for more than one second.

 

PACKAGE INCLUSION 

+  Main Station with hot air gun 

Hot air gun holder 

Air nozzles 

G001 IC popper 

Product manual 

Power cord

 

Part No. 

Description 

10094 

Heating Element 

30106S 

Hot Air Gun Plastic Handle 

S002 

Hot Air Gun Complete Handle 

20962 

Hot Air Gun Metal Pipe 

10070 

Turbine Motor

 

PARTS LIST

 

NOTE: 

Use only genuine replacement parts.

Summary of Contents for Int857A++

Page 1: ...ui Industrial Zone Nantou Zhongshan City Guangdong Province P R China http www aoyue com INSTRUCTION MANUAL Thank you for purchasing Int857A SMD Rework Station Please read the manual before using the unit Keep manual in accessible place for future reference Int857A ...

Page 2: ...flow according to the type of component being reworked 4 When proper adjustment of airflow and temperature has been set wait a few seconds for the temperature and airflow to stabilize 5 Maintain a 15mm distance between the component to be reworked and the hot air gun 6 Move the air gun in a rotating manner focusing around the component 7 When solder starts to melt and sparkle check if component ca...

Page 3: ...aintain a 15mm distance between the component to be soldered and the hot air gun 6 Move the air gun in a rotating manner focusing around the component 7 Wait until the component bonds NOTE If reworking plastic or larger components higher temperature and airflow is needed CAUTION Do not let the air stand in one position for more than one second 3 PACKAGE INCLUSION Int857A Main Station with hot air ...

Page 4: ...touch heated parts can cause severe burns Warn people around work area Thermal Protector If the thermal protector trips reduce the temperature setting or increase the air flow to decrease temperature to safe level Unit is equipped with auto shut off ability when temperature gets too high and automatically turns on when temperature dropped to a safe level Handle with Care Never drop or sharply jolt...

Reviews:

Related manuals for Int857A++