background image

4  

 

 

 

PRODUCT DESCRIPTION 

The   Aoyue   Int9378   Pro-Series   is   a   high   performance   multi-tool 

station having up to 75 watts of heating power.  It can be equipped 

with  a  variety  of  tools  such  as  a  micro  tweezer,  a  sculpting  tool,  a 

WQ-composite   Iron,   T-series   soldering   Iron,   LED   soldering   iron.  

Each tool is intelligently recognized by the station and quickly set the 

appropriate  settings   for  the  tool.   All   tools   feature  quick  heating 

ceramic heater for fast response and heat recovery.  

 

Intelligent  functions  and  features  are  available  such  as  digital 

offset,   auto   wake   function,   auto   sleep   function,   auto   tool 

regocnition,   System   lock-out   ,   quick   jump,   Temperature   Scale 

selection, LED lamp control and auto sleep.  

PACKAGE INCLUSION 

1 unit   Int9378  Pro-Series Main Station 

1 pc.   Soldering Iron 

1 pc.   2660 Soldering Iron Stand** 

1 pc.   Power Cord 

1 pc.   Instruction Manual 

 

 

** Kindly refer to soldering iron stand installation on page 2 for parts and instructions. 

13  

 

 

CARE AND MAINTENANCE 

Tip Temperature : 

 

High temperature shortens tip life and may cause thermal shock to 

components.   Always   use   the   lowest   possible   temperature   when 

soldering.   Standard   temperature   settings   are   350  to   400   degrees 

Celsius. 

Cleaning : 

 

Always  clean  the  soldering  tip  before  use  to  remove any  residual 

solder or flux adhering to it.  Use a clean and moist cleaning sponge.  

Contaminants on the tip  

have  many  detrimental  effects   including 

reduced   heat   conductivity   which   contribute   to   poor   soldering 

performance. 

After usage

 

Always clean the tip and coat it with fresh solder after use.  This 

guards against oxidation and pro-longs tip life. 

System Care: 

 

Never allow the unit to stay idle at high temperature for extended 

periods.  Utilize the automated sleep feature to conserve energy, pro-

long  tip  and  heating  element  life.  If  unit  will  not  be  used  for  long 

periods  it  is  advised  to  power  down  the  unit  and  unplug  from  the 

mains. 

Inspecting and cleaning the tip:   

◆ 

Set the temperature to 250

o

C. 

◆ 

When   the   temperature   stabilizes,   clean   the   tip   and   check   its 

condition.  If the tip is badly worn or deformed, replace it. 

◆ 

If the solder plated part of the tip is covered with black oxide, apply 

fresh solder containing flux and clean the tip again.  Repeat until all 

the oxide is removed then coat the tip with fresh solder. 

◆ 

Never file the tip to remove oxide. 

◆ 

Remaining  oxides such  as  the  yellow  discoloration  on  the  tip  shaft 

can be removed with isopropyl alcohol. 

Summary of Contents for INT9378

Page 1: ...n City Guangdong Province P R China http www aoyue com Thank you for purchasing the Aoyue Int9378 Soldering Station Please read the manual before using the unit Keep manual in accessible place for fut...

Page 2: ...afety Precautions section explains the hazards of using any type of soldering or reworking device Please read carefully and observe the guidelines in order to maximize usage and minimize the risk of i...

Page 3: ...d Display shows low tem perature levels then switches to Err2 SOLUTION The heating element is damaged Replace heating element Or check the wirings of the solder iron pen PROBLEM 3 SOLDER IRON TIP IS O...

Page 4: ...when soldering Standard temperature settings are 350 to 400 degrees Celsius Cleaning Always clean the soldering tip before use to remove any residual solder or flux adhering to it Use a clean and mois...

Page 5: ...is decided that the recently changed setting should not be saved into system memory repeatedly press the set button until the display shows the word CncL cancel Press the decrease button to exit syste...

Page 6: ...on to save and exit from the system configuration mode F SYSTEM LOCK The System lock feature disables adjustment to both temperature and system configuration The display will show SAFE when system loc...

Page 7: ...control buttons Sleep timer is configurable via the following method 1 With the unit turned On Press and hold the SET button to enter the system configuration mode 2 Repeatedly press the SET button un...

Page 8: ...tem configuration mode Wait for the display to change to 01 meaning current tool 01 9 4 Press the set button again to scroll to the Digital offset function The display shows a number with an A as its...

Reviews: