background image

 

10  

 

OPERATING GUIDELINES 

IMPORTANT: 

When adjusting the air temperature, it is strongly 

advised to  initially  increase  the  airflow  level  in  order  to

 

manage

 

the

 

system  temperature.  This  is  to  protect  the  heating  element 

inside the handle from excessive heat and avoid the possibility of 
subjecting adjacent components to thermal shock. 

5.  Adjust  the  hot  air  gun  air  temperature  using  the  hot  air  gun 

temperature adjustment buttons  (“B2 and B3” from the control 

panel).  The  display  for  Hot  Air  Gun  Temperature  will  change 

from actual temperature display to set temperature display while 

the  buttons  are  adjusted.  When  set  temperature  adjustment  is 

done   wait   a   few   seconds   for   the   display   B1   to   return   to 

displaying the actual temperature.  

 

 

 

 

 

6.  Reworking task can be started 1 minute after the desired hot air 

temperature and airflow level are reached, as also indicated from 

display panel “B1” and the airflow gauge. 

7.  When reworking is complete, return the Hot Air Gun to its holder 

and DO NOT immediately turn off the main power switch. 

8.  Deactivate the Hot Air Gun Activation button “B4” first in order to 

activate  the  auto-cooling  process.  The  system  will start  to  blow 

air (at room temperature) at a fast rate to reduce heat from the 

hot air gun and bring down the temperature to a reasonable safe 

level  of  90°C.  During  this  time,  the  display  for  hot  air  gun 

temperature will also alternate from “Off” to actual temperature 

display.  Likewise,  the  air  pressure  level  is  at  its  maximum  as 

indicated  from  the  air  flow  gauge.  Once  the  temperature  drops 

to approximately 90°C  the system will halt and display “OFF” on 

the panel. It is now safe to switch off the main power switch.  

9.  Turn OFF the main power switch. 

10. Unplug the device from the main power source. 

Summary of Contents for Int968

Page 1: ...u for purchasing Aoyue Int968 Repairing System It is important to read the manual before using the equipment Please keep manual in accessible place for future reference Deluxe Repairing System Centigr...

Page 2: ...Assembly and Preparation 8 Operating Guidelines 9 17 Care and Maintenance 18 Basic Troubleshooting Guide 19 Air Nozzles 20 This manual is designed to familiarize and instruct the op erator with the p...

Page 3: ...ackage It has several safety features such as the auto cooling process of the Hot Air Gun and overheat protection circuit It has several advanced features such as Centigrade and Fahrenheit display sel...

Page 4: ...mes created at the source Knob type Soldering Iron temperature control for simple yet efficient working temperature selection Solder Iron digital calibration Easily adjust temperature offset with a fe...

Page 5: ...C Heating Element Ceramic Heater Output Voltage 24V Tip to Ground Resistance Below 2 Tip to Ground Potential Below 2mV HOT AIR Power Consumption 550W Temperature Range 100 C 480 C Heating Element Cera...

Page 6: ...p or sharply jolt the unit Contains delicate parts that may break if unit is dropped Unplug the unit from the main power source if it will not be used for a long period Turn off power during breaks if...

Page 7: ...bsorber function switch B1 Hot Air Gun temperature display B2 Hot Air Gun decrease temperature adjustment button B3 Hot Air Gun increase temperature adjustment button B4 Hot Air Gun activation switch...

Page 8: ...ce the soldering iron to the soldering iron stand 4 Attach soldering iron spring holder as seen 5 C Soldering Iron Stand D Hot Air Gun The Hot Air Gun holder was installed on the station upside down f...

Page 9: ...ns properly secured switch ON the device by activating the main power switch 3 The display panel B1 will temporarily show the product name in a scrolling manner and then display OFF once the scroll is...

Page 10: ...te after the desired hot air temperature and airflow level are reached as also indicated from display panel B1 and the airflow gauge 7 When reworking is complete return the Hot Air Gun to its holder a...

Page 11: ...heater indicator LED indicates desired temperature is reached 5 When soldering is complete deactivate the SOLDER IRON activation switch A4 It is now safe to switch off the main power switch H System S...

Page 12: ...ocedures 1 to 6 2 Adjust system selection menu to Sel 2 then press the hot air gun increase temperature adjustment button B3 3 If successful the display B1 would show t30 indicating Hot air gun sleep...

Page 13: ...he centigrade scale or the Fahrenheit scale To switch between the two scales follow these procedures 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to 3 then press the hot air...

Page 14: ...llow System Setting procedures 1 to 6 Adjust system selection menu to 4 then press the hot air gun increase temperature adjustment button B3 6 If successful the display B1 would show 000 indicating so...

Page 15: ...air gun increase temperature adjustment button B3 2 If successful the display would show 000 indicating hot air gun digital calibration is being set 3 A lighted Soldering Iron heater indicator LED A1...

Page 16: ...adjustment menu by pressing the soldering iron function switch A4 O Calibrating the Airflow If the airflow is too low or too high due to different line voltages The airflow calibration can be digital...

Page 17: ...ibration adjustment menu by pressing the soldering iron function switch A3 5 Turn on the hot air gun function and check if additional air flow calibration is needed Repeat steps 1 to 7 each time selec...

Page 18: ...heating element is found in the middle part of the hot air gun The normal life of a heating element is 1 year under normal operating conditions Steps 1 Loosen the 3 screws that secure the handle 2 Sli...

Page 19: ...if the 4 screws that hold the pump in place are properly and tightly connected Unplug the system from the main power source before opening the case to check inside the station PROBLEM 5 THE UNIT IS VE...

Page 20: ...3 8 9 10 3 1132 5 6 13mm 16 4 7 14 11 7 1133 7 5 15mm 17 6 15 13 1134 7 5 18mm 20 6 18 13 1257 11 21mm 22 11 20 18 1258 7 6 12 7mm 12 7 10 14 1259 13 28mm 30 12 5 28 19 5 1260 8 6 18mm 20 7 7 18 14 7...

Reviews:

Related manuals for Int968