7. Selection menu is adjustable from 2 to 6. To enter the selected
function, press the hot air gun increase temperature adjustment
button “B3”.
Selection Menu
Function
0
None
1
None
2
Hot Air Gun Sleep Timer
3
Temperature Scale Adjustment
4
Soldering Iron Digital Offset
5
Hot Air Gun Digital Offset
6
AC Line Frequency Selection
9
Air Flow Calibration
OPERATING GUIDELINES
J. Activating Hot Air Gun Auto-Sleep Mode
The hot air gun’s SLEEP mode can be activated by following the set
of procedures below:
1. Follow System Setting procedures 1 to 6.
2. Adjust system selection menu to “Sel 2”, then press the hot air
gun increase temperature adjustment button “B3”.
3. If successful the display “B1” would show “t30” indicating Hot air
gun sleep timer is being set.
4. Adjust the sleep timer with the hot air gun increase and decrease
temperature adjustment buttons “B3 and B2”.
5. Sleep timer is adjustable from 1 to 60 minutes with “OFF”
signifying sleep timer is turned off.
6. Save the selected timer settings and exit from the sleep timer
adjustment menu by pressing the soldering iron function switch
“A4”.
7. If the sleep mode is activated the sleep timer will start counting
down once the Hot air gun is placed on it’s holder and the hot air
gun function switch “B4” is activated.