7.  Selection  menu  is  adjustable  from  2  to  6.  To  enter  the  selected 

function,  press  the  hot  air  gun  increase  temperature  adjustment 

button “B3”.  

   Selection Menu 

Function 

None 

None 

Hot Air Gun Sleep Timer 

Temperature Scale Adjustment 

Soldering Iron Digital Offset 

Hot Air Gun Digital Offset 

AC Line Frequency Selection 

Air Flow Calibration 

 

OPERATING GUIDELINES 

J.  Activating Hot Air Gun  Auto-Sleep Mode 

 

The hot air gun’s SLEEP mode can be activated by following the set 

of procedures below: 

1.  Follow System Setting  procedures 1 to 6. 

2.  Adjust  system  selection  menu  to  “Sel  2”,  then  press  the  hot  air 

gun increase temperature adjustment button “B3”.  

3.  If successful the display “B1” would show “t30” indicating Hot air 

gun sleep timer is being set. 

4.  Adjust the sleep timer with the hot air gun increase and decrease 

temperature adjustment buttons “B3 and B2”.  

5.  Sleep   timer   is   adjustable   from   1   to   60   minutes   with   “OFF” 

signifying sleep timer is turned off. 

6.  Save  the  selected  timer  settings  and  exit  from  the  sleep  timer 

adjustment  menu  by  pressing  the  soldering  iron  function  switch 

“A4”. 

7.  If  the sleep  mode  is  activated  the  sleep  timer  will start  counting 

down once the Hot air gun is placed on it’s holder and the hot air 

gun function switch “B4” is activated. 

Summary of Contents for Int968

Page 1: ...u for purchasing Aoyue Int968 Repairing System It is important to read the manual before using the equipment Please keep manual in accessible place for future reference Deluxe Repairing System Centigr...

Page 2: ...Assembly and Preparation 8 Operating Guidelines 9 17 Care and Maintenance 18 Basic Troubleshooting Guide 19 Air Nozzles 20 This manual is designed to familiarize and instruct the op erator with the p...

Page 3: ...ackage It has several safety features such as the auto cooling process of the Hot Air Gun and overheat protection circuit It has several advanced features such as Centigrade and Fahrenheit display sel...

Page 4: ...mes created at the source Knob type Soldering Iron temperature control for simple yet efficient working temperature selection Solder Iron digital calibration Easily adjust temperature offset with a fe...

Page 5: ...C Heating Element Ceramic Heater Output Voltage 24V Tip to Ground Resistance Below 2 Tip to Ground Potential Below 2mV HOT AIR Power Consumption 550W Temperature Range 100 C 480 C Heating Element Cera...

Page 6: ...p or sharply jolt the unit Contains delicate parts that may break if unit is dropped Unplug the unit from the main power source if it will not be used for a long period Turn off power during breaks if...

Page 7: ...bsorber function switch B1 Hot Air Gun temperature display B2 Hot Air Gun decrease temperature adjustment button B3 Hot Air Gun increase temperature adjustment button B4 Hot Air Gun activation switch...

Page 8: ...ce the soldering iron to the soldering iron stand 4 Attach soldering iron spring holder as seen 5 C Soldering Iron Stand D Hot Air Gun The Hot Air Gun holder was installed on the station upside down f...

Page 9: ...ns properly secured switch ON the device by activating the main power switch 3 The display panel B1 will temporarily show the product name in a scrolling manner and then display OFF once the scroll is...

Page 10: ...te after the desired hot air temperature and airflow level are reached as also indicated from display panel B1 and the airflow gauge 7 When reworking is complete return the Hot Air Gun to its holder a...

Page 11: ...heater indicator LED indicates desired temperature is reached 5 When soldering is complete deactivate the SOLDER IRON activation switch A4 It is now safe to switch off the main power switch H System S...

Page 12: ...ocedures 1 to 6 2 Adjust system selection menu to Sel 2 then press the hot air gun increase temperature adjustment button B3 3 If successful the display B1 would show t30 indicating Hot air gun sleep...

Page 13: ...he centigrade scale or the Fahrenheit scale To switch between the two scales follow these procedures 1 Follow System Setting procedures 1 to 6 Adjust system selection menu to 3 then press the hot air...

Page 14: ...llow System Setting procedures 1 to 6 Adjust system selection menu to 4 then press the hot air gun increase temperature adjustment button B3 6 If successful the display B1 would show 000 indicating so...

Page 15: ...air gun increase temperature adjustment button B3 2 If successful the display would show 000 indicating hot air gun digital calibration is being set 3 A lighted Soldering Iron heater indicator LED A1...

Page 16: ...adjustment menu by pressing the soldering iron function switch A4 O Calibrating the Airflow If the airflow is too low or too high due to different line voltages The airflow calibration can be digital...

Page 17: ...ibration adjustment menu by pressing the soldering iron function switch A3 5 Turn on the hot air gun function and check if additional air flow calibration is needed Repeat steps 1 to 7 each time selec...

Page 18: ...heating element is found in the middle part of the hot air gun The normal life of a heating element is 1 year under normal operating conditions Steps 1 Loosen the 3 screws that secure the handle 2 Sli...

Page 19: ...if the 4 screws that hold the pump in place are properly and tightly connected Unplug the system from the main power source before opening the case to check inside the station PROBLEM 5 THE UNIT IS VE...

Page 20: ...3 8 9 10 3 1132 5 6 13mm 16 4 7 14 11 7 1133 7 5 15mm 17 6 15 13 1134 7 5 18mm 20 6 18 13 1257 11 21mm 22 11 20 18 1258 7 6 12 7mm 12 7 10 14 1259 13 28mm 30 12 5 28 19 5 1260 8 6 18mm 20 7 7 18 14 7...