background image

Network port cable function information

1

2

+24VDC

3

RS485+B

4

RS485+A

5

GND

6

GND

7

8

9

Metal shield

PE

The output wiring diagrams of pins 7 and 8 are as follows:

Button function instructions

Unlock, press +/- to switch the display of working address, cleaning cycle, working 

environment temperature/humidity,  alarm threshold

&7

7+

ĺ 

$/

7+

ĺ 

&$/ĺ 2.

'LVSOD\LQIRUPDWLRQGHVFULSWLRQ

7000

Display the real-time high-voltage output value of the high-voltage power supply

7000VAC

A00

Display the working address of the high-voltage power supply 

00

E15

Display the cleaning cycle of the matching ion bar

15

Unit

day

C19

Display the internal working environment temperature of the high-voltage power supply

19

H19

Display the internal working environment humidity of the high-voltage power supply

19%RH

1000

Display the alarm threshold of the high-voltage power supply: 1000VAC

&$/ĺ

ĺ 

Installation Guide

1. Insert the national standard power cord plug into the mains socket.

2. Insert the high-voltage connector of the static elimination device into the high-voltage output socket of the power supply and connect its ground 

terminal to the ground stud of the high-voltage power supply.

3. The switch indicator and status indicator light on(Green light on when working normally) and the display showing the working voltage value 

normally indicates the power supply working normally when turn on the power switch.

4. One end of the communication network cable should be inserted into the RJ45 communication socket on the front panel of the power supply,

and the other end should be connected to a monitoring terminal or connected to a PC through a USB-485 converter If communication is 

required. The port wiring and panel descriptions are as follows:

Orange/White-orange

Blue

White-blue

Green

White-green

Brown

White-brown

HV

AL

High voltage alarm

ACT

Power on indication 

Clean

Cleaning indication

5

The cleaning cycle of the high-voltage power supply can be set by the remote control, as shown in the table below:

Unlock

Run / Pause

Parameter display

Adjust cleaning cycle

Adjust alarm threshold

Confirm

Reset

Unlock before adjusting operating parameters

Device starts running when power is on. Press "STOP" to standby and no high voltage 

output.  Press "RUN" again and the device will start working.

Press CT

TH

 first, then press +/- to increase or decrease the cleaning cycle (Default 30 

days, adjustment range is 1-60 days)

Press AL

TH

 first, then press +/- to increase or decrease the high voltage alarm threshold 

(Default 1000V, adjustment range is 500-2000V)

Press CAL first, then press OK to confirm after adjusting the output parameter

5HVHW

3UHVV&$/ILUVW

WKHQSUHVV

(eg

High voltage from 7000VAC  1000VAttenuation  6000VAC alarm)

HV Alarm signal:Normal--always 

open

Abnormal--always close

Power signal :Normal--always close

cleaning signal

:Clean--always open

Summary of Contents for AP-AY151X

Page 1: ...uct Instruction Manual Digital display intelligent AC power supply Shanghai Anping Static Technology Co Ltd Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China Tel 86 21 64517676 Fax 86 21 64517673 ...

Page 2: ...ws the equipment working voltage in real time 6 The power supply with communication function can be monitored online on the adapting software 7 With short circuit protection function it will automatically cut off the power supply when the device is short circuited Product details and dimensions Model AP AY1517 2517 AP AY1515 2515 Input voltage AC220V 50Hz or AC110V 60Hz Output voltage AC7000V No l...

Page 3: ... normally indicates the power supply working normally when turn on the power switch 4 One end of the communication network cable should be inserted into the RJ45 communication socket on the front panel of the power supply and the other end should be connected to a monitoring terminal or connected to a PC through a USB 485 converter If communication is required The port wiring and panel description...

Page 4: ...r from the date of purchase However this commitment does not apply to a The device is incorrectly used or installed b Damage caused by negligence or accident during use c Modified disassembled or repaired by other service departments not authorized by Anping Company 3 AP T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above NO 1 2 ...

Reviews: