1. Please read the instruction manual carefully before installing and using this equipment.

2. The working input power of the power box must be reliably connected to the grounding wire of the electrical power supply cable and the 

grounding resistance should be less than 4 ohm; Otherwise, it is easy to cause abnormal or even damage of ion bar and high voltage power supply.

3. Do not use this equipment in environment where humidity is > 70%.

4. It is strictly forbidden to use this equipment in flammable and explosive environments.

5. Unauthorized disassembly of the product is strictly prohibited, internal maintenance and repair must be performed by professionals.

6. It is strictly forbidden to touch liquid during use, otherwise an abnormality may occur and cause electric shock or fire.

7. Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.

8. The product is specially designed for eliminating static electricity. It is strictly forbidden to use it for other purposes. Any abnormal use may cause 

machine failure, electric shock, fire and other accidents.

9. Please check the input voltage before powering on the product. Any power supply that does not meet the specifications will cause damage to the 

product.

10.Please check the product power cord regularly and replace it immediately if it is damaged. Otherwise it is easy to cause problems such as electric 

leakage and abnormal operation. 

1. AP-AY151X/251X digital display intelligent AC power supply has undergone rigorous testing and aging treatment before ex-work. Its

performance has completely reached the relevant indicators marked in the usage instruction.

2. AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge within one

year from the date of purchase. However, this commitment does not apply to:
a. The device is incorrectly used or installed.
b.  Damage caused by negligence or accident during use.
c. Modified, disassembled or repaired by other service departments not authorized by Anping Company.

3. AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.

NO

1

2

3

4

5

Maintenance

It should be stopped and repaired by professional maintenance personnel when the red switch work indicator on the back panel of the high voltage 
power supply is off, or the status indicator on the front panel is red or off, or the display is abnormal. It can be used only after the electrical 
performance indicators are normal.

Problems

Reasons

Solutions

The switch indicator on the 

back panel is off

Poor contact of the power cable

Check whether the power cable is in good condition and  

securely connected

No power supply

Check the on-site power supply lines

The status indicator on the 

front panel is red

No power supply from high voltage transformer

Return to factory for maintenance

High voltage transformer is damaged

Return to factory for maintenance

High-voltage components is damaged

Return to factory for maintenance

The panel indicator light is blue

Cleaning indication

Ion bar and power supply cleaning maintenance

The display is abnormal or fuzzy

Abnormal discharge

Check the connection between the high-voltage plug of the ion 

bar high-voltage cable and the power supply high-voltage socket 

to confirm that the plug is inserted in place

The product is smoky or burnt

The high-voltage transformer or high-voltage 

components are damaged or the insulation of 

the discharge socket is damaged

Return to factory for maintenance

Safety warning

W

arning

After-sales service

Packaging accessories

1

Manual   

2

Certificate of conformity 

3

National standard power cord  

4

Remote control  

5

Network cables, converters and matching software are optional if communication function is required

Summary of Contents for AP-AY151X

Page 1: ...uct Instruction Manual Digital display intelligent AC power supply Shanghai Anping Static Technology Co Ltd Website www ap static com Address 3 F Building 27 No 69 Guiqing Road Shanghai China Tel 86 21 64517676 Fax 86 21 64517673 ...

Page 2: ...ws the equipment working voltage in real time 6 The power supply with communication function can be monitored online on the adapting software 7 With short circuit protection function it will automatically cut off the power supply when the device is short circuited Product details and dimensions Model AP AY1517 2517 AP AY1515 2515 Input voltage AC220V 50Hz or AC110V 60Hz Output voltage AC7000V No l...

Page 3: ... normally indicates the power supply working normally when turn on the power switch 4 One end of the communication network cable should be inserted into the RJ45 communication socket on the front panel of the power supply and the other end should be connected to a monitoring terminal or connected to a PC through a USB 485 converter If communication is required The port wiring and panel description...

Page 4: ...r from the date of purchase However this commitment does not apply to a The device is incorrectly used or installed b Damage caused by negligence or accident during use c Modified disassembled or repaired by other service departments not authorized by Anping Company 3 AP T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above NO 1 2 ...

Reviews: