background image

8

 

 

NOTE:

 

!

 

 

before disconnecting the device from a computer, press the 

Disconnect device

 button 

 

in the event of no response:  

 

in the 

Software options

, check the number of the COM port 

 

make sure that the serial port drivers have been installed correctly (chapter 7) 

 

disconnect for a few seconds and then reconnect the recorder to the USB port 

 

restart the computer 

 

take the battery out of the recorder for a few seconds (as described in chapter 12) 

In the event of indications different than the actual value of the input signal, the zero and the sensitivity of a 
sensor can be tuned: parameters 11: 

calO

 (zero) and 12: 

calG

 (sensitivity). 

 
Table 9. List of configuration parameters 

No. 

Name 

Description of parameter 

User settings

 

RTC

    (1)

 

internal real time clock (chapter 9.1) 

 

RECORDING OPTIONS

 (chapter 9.2)

 

Start

 

recording start time 

 

Stop

 

recording end time 

 

MPer 

data recording interval 

 

SDest 

selection of memory to save archive files (to record data) 

 

CONFIGURATION OF THE MEASUREMENT INPUT

 (chapter 9.3) 

inp 

type of measurement input 

 

rrtd 

total resistance of leads for 2-wire RTD sensors and 700 Ω 

 

cjte 

temperature of cold thermocouple tips 

 

dot 

position of the point/resolution 

 

rbot 

bottom of the indication range (start of the scale) for 0 mA, 4 mA, 0 V, 0 mV, and 
0 Ω 

 

10 

rtop 

top of the indication range (end of the scale) for 20 mA, 10 V, 60 mV, and 700 Ω 

 

11 

calO 

calibration of the zero 

 

12 

calG 

calibration of the inclination 

 

ACCESS OPTIONS

 (chapter 9.4) 

13 

bloc 

block of the “

COPY

” button

 

 

14 

Pass 

card authorization password

 

 

15 

Prot 

SD card authorization demand 

 

16 

ID       

(1)

 

identification number, ID (recorded in the csv archive file) 

 

DISPLAY OPTIONS

 (chapter 9.5) 

17 

LCDmod 

operation mode of the display 

 

18 

LCDupd 

interval of display update in the continuous mode

 

 

19 

LCDch 

value to be displayed 

 

CONFIGURATION OF ALARMS

 (chapter 9.6) 

20 

AHigh 

high alarm for the measured value 

 

21 

Alow 

low alarm for the measured value 

 

Notes: (1)

 – parameter accessible only from the level of ARSOFT-CFG WZ1 (on-line configuration) 

Summary of Contents for AR234

Page 1: ...USER INSTRUCTION DATA RECORDER AR234 Version 1 0 5 2016 07 08 ...

Page 2: ...NAND THE ELECTRICAL CONNECTIONS 6 7 CONNECTING TOA COMPUTERAND INSTALLATION OF DRIVERS 6 8 INSTALLATION OF SOFTWARE 7 9 SETTING OF THE CONFIGURATION PARAMETERS 7 9 1 TIMEAND DATE 9 9 2 RECORDING OPTIONS 9 9 3 CONFIGURATION OF THE MEASUREMENT INPUT 9 9 4 ACCESSAND IDENTIFICATION OPTIONS 10 9 5 DISPLAY OPTIONS 11 9 6 CONFIGURATION OF THEALARM OUTPUT 11 10 USEAND FUNCTIONS OF THE SD MMC CARD 12 11 VI...

Page 3: ...ttery LCD display that shows the measured values messages and errors long operation time with a new battery up to 5 years depending on the recording interval the presence of an SD card the operating temperature of the device and the mode of operation of the display possibility to transfer archived and configuration data on an SD card internal real time clock with a battery backup power supply comp...

Page 4: ...omputer 2 m long a CD with the drivers and the software Windows XP Vista 7 8 10 a user instruction a warranty card 4 TECHNICAL DATA A universal input programmable measurement range Pt100 RTD 3 or 2 wire 200 850 C Ni100 RTD 3 or 2 wire 50 170 C thermocouple J 40 800 C thermocouple K 40 1200 C thermocouple S 40 1600 C thermocouple B 300 1800 C thermocouple R 40 1600 C thermocouple T 25 350 C thermoc...

Page 5: ...ABS UL94 V0 white Protection rating IP20 no protection against ingress of water and condensation Enclosure dimensions 80 x 80 x 25 mm Operating position any Weight approx 100 g with a battery Electromagnetic compatibility EMC immunity according to the PN EN 61000 6 2 2002 U standard emissivity according to the PN EN 61000 6 3 2002 U standard 1 operation time depends on the measurement period the p...

Page 6: ...indows XP Vista 7 8 10 system detects the recorder named APAR USB DEVICE and demands installation of drivers In the find new device wizard manually indicate the location of the drivers on a CD ROM the DRIVERS catalog In the Windows XP system the installation procedure is the following 1 Choose the option No not this time and press the Continue button 2 Choose Install from a list or a specific loca...

Page 7: ...bility to print input data is uploaded one time from a csv text file created in the internal memory in the recorder or on an SD MMC card chapter 11 The latest versions of the aforementioned programs are also available at the website www apar pl The detailed descriptions of the aforementioned applications can be found in the installation folders 9 SETTING OF THE CONFIGURATION PARAMETERS All the con...

Page 8: ... memory to save archive files to record data CONFIGURATION OF THE MEASUREMENT INPUT chapter 9 3 5 inp type of measurement input 6 rrtd total resistance of leads for 2 wire RTD sensors and 700 Ω 7 cjte temperature of cold thermocouple tips 8 dot position of the point resolution 9 rbot bottom of the indication range start of the scale for 0 mA 4 mA 0 V 0 mV and 0 Ω 10 rtop top of the indication rang...

Page 9: ...9 59 2008 06 01 00 00 00 2 Stop recording end time 1 date 01 06 2008 31 12 2099 time 00 00 00 23 59 59 2008 06 01 00 00 00 3 MPer 2 data recording interval 10 s 24 hrs increment 10 s 10 s 4 SDest the memory where the archive files csv are to be recorded 3 internal The csv files are created only in the internal memory auto automatic selection auto archive files csv are created only on an SD MMC car...

Page 10: ... zero offset 50 0 50 0 C or 500 500 units 2 0 0 C 12 calG calibration of the inclination sensitivity gain 85 0 115 0 100 0 Notes 1 in the case of 3 wire sensors there is automatic line resistance compensation and parameter 6 rrtd must be equal to 0 00 Ω 2 applies to analog inputs mA V mV Ω 9 4 ACCESS AND IDENTIFICATION OPTIONS Table 9 4 Configuration parameters concerning the access and identifica...

Page 11: ...guration parameters Parameter Range of variability of the parameter and description Default settings 17 LCDmod 1 display operation mode economy or continuous econom 18 LCDupd 1 interval of display update in the continuous mode 10 s 24 hrs 10 s increment 2 minutes 19 LCDch value to be displayed measurement and internal temperature measurement and int temp measurement only 9 6 CONFIGURATION OF THEAL...

Page 12: ...ith off line configuration consequently an appropriate cfg file must be present or absent when parameter 15 Prot off so as to avoid undesirable reconfiguration of the recorder in order to extend the operation of the battery it is recommended to use SD MMC cards of reputable brands e g SanDisk Kingston or GoodRam formatted in the FAT16 file system in the case of cards larger than 2 GB there is a ri...

Page 13: ...fferent than the one that is set in the configuration chapter 9 3 parameter 5 inp b other elements indicated by the LED s on the side of the housing and on the LCD display LED Description of message READ WRITE writing to reading from the internal memory or the SD MMC card also during recording of a measurement recording is active a short flash every 10 seconds STATUS transmission through the virtu...

Page 14: ...ass memory is supported internal memory or the SD MMC card and during operation of the ARSOFT CFG WZ1 software keep a copy of the current configuration file AR234 cfg in external memory SD MMC card computer disk etc for the purpose of archiving and future off line configuration If the recorder does not respond the battery can be taken out for a short time and its charging level can be checked if t...

Reviews: