background image

DKR 250

 Installation and user manual

 2018/02d 

Basic error of the thermometer  ±2,5% of the range 

scale

Weight 

             approx. 440g

Protection

IP 20

Operating voltage

250V

Minimum working voltage

24V

Frequency

50Hz

Operating current

50mA

Connection

recommended to use
flat cords 
H03VH-H 2x0,5 
(ČSN   EN   5052-2-71  
or
ČSN EN 5052-2-11)

Category of use

ohmic load,
auxiliary relay

Lifetime

10 000 operating
cycles

DKR   thermometer  meets  these   technical   standards:
EN 60947-5-1 ed.2 (35 4101), EN 60947-1 (35 4101),
ČSN EN 60529 (33 0330), ČSN 33 0360 ed.2, ČSN
33 2000-1 ed.2.

Function description and commissioning:
Thermometer DKR 250,

 

maximal

 

version

Adjustable pointer of maximal temperature is located
to the right  from contact  pointer. When  temperature
raises,   contact   pointer   moves   closer   to   adjustable
pointer.   When   switching   temperature   is   reached,
contacts are connected. 

Thermometer DKR 250,

 

minimal

 

version

Adjustable pointer of minimal temperature is located
to   the   left   from   contact   pointer.   When   temperature
lowers,   contact   pointer   moves   closer   to   adjustable
pointer.   When   switching   temperature   is   reached,
contacts are connected. 

Set the desired switching (signalling) temperature 
manually by adjustable indicator using a suitable 
screwdriver.

Notice:

With the minimum DKR thermometer, set the pointer 
to the lower temperature limit (-30 ° C, 0 ° C) before 
the measured temperature drops below the set start-
up temperature (finished work, device turned off, etc.).

Maintenance instructions:

If   required   inspect   state   of   DKR   thermometer,
contacts   and   power   cables.   If   the   thermometer   is
damaged   or   contacts  are   wear   off,  then   disconnect

the  thermometer from  power  and  do  not  use  it   any
more.

Storage conditions:

Thermometers must be stored in a dry room with  a
maximum humidity of 70% and temperature from 0 °
C   to   30   °   C,   without   sudden   temperature   changes.
The   storage   room   must   be   free   of   harmful   gases.
Handle it with extra caution, no shocks at all.

Disposal:

Dispose   it   accordingly:   Find   recycle   service   to   deal
with it.

Possible minor faults and their fix:

Minimum DKR thermometer with a long-term drop in
the   temperature   below   the   set   temperature,   may
deteriorate or even ruin the thermometer.

All DKR thermometer defects are removed exclusively
by the manufacturer.

Warranty:

Assuming   that   the   product   is   placed,   plugged   and
used in accordance with the instructions found in the
user   manual,   the   manufacturer   provides   a   warranty
according to the law, unless otherwise agreed.

The manufacturer will  refuse warranty  service  if  the
device has been damaged: 

during   transport   and   storage   by   the   client,or
his/her customers

when   installing   or   disassembling   to   the   client's
equipment, or his/her customers

when   improper   handling   and   installation   to   a
device other than that specified in the instruction
manual

if the DKR has been exposed to an environment
other than that specified in the manual

Warranty and post-warranty repairs

Warranty  and post-warranty  repairs are  provided by
the manufacturer. Pack and ship the faulty product to:

APATOR METRA s.r.o.

Havlíčkova 919/24
787 01 Šumperk
Czech Republic

Tel.: 

583 718 263

Fax: 

583 718 150 

E-mail: 

prodej@metra-su.cz

 

www:

http://www.metra-su.cz

2 / 2