E-ITN 30.xx EX (EXNR) with remote
Installation, servicing and operatiion manual
M2016/08b [EN]
•
start of summer heating period
•
start of winter heating period
•
start of billing period
•
optional display of following data
◦
current radiator temperature
◦
current surrounding temperature
◦
date of the beginning of the billing period
◦
current date
◦
current time
•
length of the cable to the remote sensor
5.2.2. List of adjustable parameters of E-ITN 30.6 EX (EXNR) with remote sensor
•
allocator mode
•
radiator type
•
radiator output (20 to 5000 W, with resolution 20 W)
•
Kc factor (0.800 to 1.700 [ - ], with resolution 0.001 [ - ])
•
time shift from UTC
•
start date in the mode of waiting for start date
•
start of summer heating period
•
start of winter heating period
•
start of billing period (must be in interval <1 ; 28>, the month serves for computing the yearly value –
information accessible through IR interface).
•
optional display of following data
◦
current radiator temperature
◦
current surrounding temperature
◦
date of the beginning of the billing period
◦
current date
◦
current time
•
length of the cable to the remote sensor
•
the shift of the 12 min interval transmissions towards the beginning and end of the summer heating
period in the range <0; +60> days.
•
radio data (varies with SW version):
◦
version SW = 7 standard format without encryption
◦
version SW = 8 standard format with AES – 128 encryption
◦
version SW = 5 extended format without encryption
◦
version SW = 6 extended format with AES – 128 encryption
•
16 B encryption key ytes with customisible 6 B (12 characters: 0 – 9, A - F)
22 / 39