E-ITN 30.xx EX (EXNR) with remote
Installation, servicing and operatiion manual
M2016/08b [EN]
7.5. I
NSTALLATION
ON
SEGMENTED
RADIATORS
Picture 7: Mounting material for the installation of E-ITN 30.xx EX (EXNR) with remote sensor on segmented
radiators
1
Remote sensor assembly
8
Bolt M4x25
2
Remote sensor back plate
9
Bolt M4x35
3
Spacer 45
10
Bolt M4x50
4
Clamp
11
Bolt M4x80
5
Clamp III
12
Bolt M4x115
6
Clamp IV
13
Nut M3 spec.
7
Washer 4
14
Clamp FONAL
7.5.1. Description of installation
The back plate should be installed on the radiator with clamps and bolts as follows:
•
place back plate into the final location and fix with clamp and bolt through the centre hole,
•
tighten to a torque 1 Nm,
•
place the sensor into the back plate profile groove from top, align it with the base plate and push
allocator to connect it with the back plate.
When using cast iron radiator with a very rough surface (large grain) it is recommended to grind off these
grains at the place where back plate will be installed.
After installation, installation protocol has to be filled in (including date of installation, room, type of the
radiator, allocator serial number, etc.).
7.5.2. Installation differences
a) When installing on the radiators with difficult access (KALOR 3,TERMO) follow these steps:
•
insert the mounting bolt through centre hole of the back plate and screw it on several threads to
the clamp,
•
slide prepared set from the top between radiator segments (clamp is in upright position) and
place in the mounting height,
•
tighten the back plate to a torque 1 Nm.
30 / 39