E-ITN 30.xx EX (EXNR) with remote
Installation, servicing and operatiion manual
M2016/08b [EN]
Power supply
lithium battery 3,0 V
Material
ABS + PC / Al – F22
IP code
IP 42
Conformity
EN 834
Operating frequency
868 MHz
Transmitting power
< 5 mW
Class of working cycle
1 (duty cycle percentage <0,1 %)
Transmission length
~ 6 ms
Length of the cable to the remote
sensor
1.5 m, 2 m, 2,5 m (standard) and 3 m
Radio data transmission intervals
E-ITN 30.2 EX (EXNR) with remote sensor
•
30 [s] seconds first month after the billing period beginning
•
240 [s] seconds rest of the year
E-ITN 30.4
•
30 [s] seconds first 3 days after the billing period beginning
during all months except July and August
•
240 [s] seconds rest of the year
Transmission range
up to 250 m (outside the building, with additional panel antenna)
Rem
.
: all metal parts of construction (switch rooms, armouring, lifts,
etc.) can negatively affect the range of radio signal.
Data coding
yes
Data available via radio interface
(for exact data structure see
manual for decoding software)
E-ITN 30.2 EX (EXNR) with remote sensor, E-ITN 30.4 EX (EXNR)
with remote sensor
•
reading date
•
serial number
•
value for the last billing period
•
alphanumeric code for the last billing period and its validity
•
current value
•
electronic seal status
•
indication of the remote sensor
•
billing period start date
Data available via IR interface (for
exact data structure see manual
for decoding software)
E-ITN 30.2 EX (EXNR) with remote sensor
•
reading date
•
serial number
•
date of yearly billing period beginning
•
value for the last billing period
•
alphanumeric code for the last billing period and its validity
•
consumption for current and last 11 months
•
current consumption
•
max. radiator temperature in last 11 months
•
min. radiator temperature in last 11 months
•
average radiator temperature for current and last 11 months
8 / 39