Apeks Supercritical: The Duplex
™
Installation Manual
19
Revision Date 04/11/2019
3.3.5.2.
Separator Vessel Stand to Extractor Vessel Stand
– There are thirteen ¼
"
red airlines
that run between the separator and extractor stand. These lines are connected with a
push-to-connect coupling and labeled on both sides. Fully insert the tubing into the
coupling to connect. See Figure 13.
3.3.5.3.
Separator Vessel Stand to Diaphragm Compressor
– There is one
¼"
red airline that
runs between the separator stand and the diaphragm compressor. This line is connected
with a push-to-connect coupling and labeled on both sides. Fully insert the tubing into the
coupling to connect. See Figure 14.
Figure 13:
Airline connections
Figure 14:
Airline connection to Compressor