STEP 5     MORTISE CYLINDER INSTALLATION 

 

 

Using  a  Philips  Head  Screwdriver, 
remove the eight (8) #10-32 x 5/8” 
screws on the back of the eForce

®

 

and gently lift the back plate off the 
housing. 

 

 

C

AUTION

!

 There are wires connect-

ing  the  housing  and  back  plate 
assembly.  Handle with care. 

 

 

Do not over-tighten!

 

 
 
 
 

 

Install  Cylinder  into  housing.  Se-
cure and fasten with supplied lock-
ing ring using locking ring spanner 
tool.  (F

IG

. 15) 

 

 

Gently  place  back  plate  back  on 
housing  and  secure  with  eight  (8) 
#10-32 x 5/8” screws. 

 

 

C

AUTION

!

 There are wires connect-

ing  the  housing  and  back  plate 
assembly.  Handle with care. 

 

 

Do not over-tighten!

 

 

 

Do not use Dummy Cylinder!

 

 

 
 

 

 

June 2013 

80-0180-347 Rev. A 

HUB WIRING  

 

The Aperio hub connects to the Access Control system via Wiegand 
wiring.  The hub requires 8-24VDC power (250mA).  The hub has four 
form C relays that can be used to transmit door position status, re-
quest to exit, low battery signal and a tamper signal.  The Hub con-
nects to the lock wirelessly. 

 

 

Scan the QR Codes 
to view installation 
videos online. 

 

*Note:

 the 

Green LED

 input is used to grant access to the 

lock.  If the Green LED signal is not available to indicate ap-
proved access, the input can be activated by another unlock 
signal or relay tied to the GRN LED pin 

Wiring the Hub 

Mounting the Hub 

Summary of Contents for eForce A100 A100-3090H

Page 1: ... S 51st St Suite 102 Phoenix AZ 85044 Phone 800 872 3267 Fax 800 232 7329 www adamsrite com NORMAL OPERATION LOCK INDICATIONS Aperio eForce A100 Narrow Stile Keyless Entry Adams Rite Manufacturing Co Phone 800 872 3267 www adamsrite com Owner s Manual Installation Instructions For Models A100 3090H ...

Page 2: ...n credential card in front of eForce If the eForce emits one short tone but lock does not activate check Wiegand data lines for connectivity and proper connec tion Green light comes on but lever will not retract latch or deadbolt Check the eForce body connection with lock latch mechanism Check the spindle length see installation instructions Check for proper door preparation refer to door template...

Page 3: ...evice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference w...

Page 4: ... Exit Devices Corbin Russwin ED4000 Series and SARGENT 8500 Narrow Design Rim Exit Devices OPERATIONAL SPECIFICATIONS IEEE 802 15 4 UHF Interface operating at 2 4GHz iCLASS or PROX Reader technology AES 128 bit encryption 4 AA battery operated Operating Temperature Range 31 to 150 F 35 to 65 C Operating Humidity Range 5 to 95 relative humidity non condensing June 2013 17 80 0180 347 Rev A STEP 8 B...

Page 5: ...are valid The LED will change states from off to green and a short audible tone will be heard to indicate a valid unlock status Rotate the lever to gain entry into the building Deadlatch versions will return to a secured locked state after the access control system unlock pe riod has expired Deadbolt versions will remain unlocked until the deadbolt is thrown again NOTE the access control system wi...

Page 6: ...the Hub The included hub mounting adapter plate can be used to mount the hub on a single or double gang box A B C June 2013 15 80 0180 347 Rev A STEP 6 REX DPS CABLE INSTALLATION PIN WIRE COLOR FUNCTION CONTACT 1 Yellow D P S Door Position Switch N C 2 Blue COM 3 Brown N O 4 Orange N C REX Request to Exit 5 White COM 6 Green N O Using a Phillips Head screwdriver remove the eight 8 10 32 x 5 8 scre...

Page 7: ...are wires connect ing the housing and back plate assembly Handle with care Do not over tighten Do not use Dummy Cylinder June 2013 7 80 0180 347 Rev A HUB WIRING The Aperio hub connects to the Access Control system via Wiegand wiring The hub requires 8 24VDC power 250mA The hub has four form C relays that can be used to transmit door position status re quest to exit low battery signal and a tamper...

Page 8: ...tem Description Qty 1 Mounting Bracket Part 22 9076 1 2 10 32 X 5 8 Phillips Pan Head Screws w Lockwasher 4 3 Spindle Part 22 9154 1 4 5 64 Allen Key 1 5 Cylinder Locking Ring Part 24 0061 1 6 Locking Ring Spanner Tool Part 22 0594 1 FIG 1 June 2013 13 80 0180 347 Rev A STEP 4 HANDING THE eForce The eForce is shipped in a non handed neutral position with the access cover off as shown To hand the e...

Page 9: ...screw and secure with the two 2 brass cam plug screws Cam Plug must be positioned below door sur face CYLINDER ACTUATOR SCREW FIG 11 FIG 10 FIG 12 June 2013 9 80 0180 347 Rev A STEP 1 DOOR PREPARATION FIG 2 Select the stick on template to match the appli cation For Yale Corbin Russwin and SARGENT exit devices use template 80 0180 396 01 Mark the backset and horizontal centerlines Apply clear templ...

Page 10: ... FIG 6 For 2 thick doors add two notches FIG 6 Insert T end into exit devices Fourteenth notch FIG 5 Sixth notch Insert Flat end into exit devices FIG 4 Fifth notch Insert Flat end into exit devices June 2013 11 80 0180 347 Rev A STEP 3 CONFIGURE FOR LOCK SERIES Mortise Latch Application A100 3090H for 4500 4900 including 8300 8400 Exit Devices Configure the supplied cam plug to match the hand of ...

Reviews: