System Components

Door Station

Monitor

EVBPSBB 

Lock Power Supply

EV-EXIT 

Push To Release 

EV-EBG 

Emergency Release

EV-ML-250/500XT 

Electro-magnetic Lock

ENTERD 

Electric Lock

Optional Accessories

System Power Supply

APKITBLK Manual.indd   3

26/04/2017   09:39:57

Summary of Contents for APKITBLK

Page 1: ...U S E R M A N U A L w w w e s p u k c o m A P K I T B L K C O L O U R V I D E O D O O R E N T R Y S Y S T E M APKITBLK Manual indd 1 26 04 2017 09 39 55 ...

Page 2: ...P Find this product online elandcables com Cables Accessories LAN Cable Cat 5E UTP PVC Cable Contents System Components 3 Installation 4 System Connections Example 1 5 System Connections Example 2 6 Lock Connections Example 1 7 Lock Connections Example 2 8 User Guide 9 Installer s Guide 10 APKITBLK Manual indd 2 26 04 2017 09 39 55 ...

Page 3: ...tion Monitor EVBPSBB Lock Power Supply EV EXIT Push To Release EV EBG Emergency Release EV ML 250 500XT Electro magnetic Lock ENTERD Electric Lock Optional Accessories System Power Supply APKITBLK Manual indd 3 26 04 2017 09 39 57 ...

Page 4: ...ew The camera needs to point in the direction of where a visitor will stand during operation Site the indoor monitor to suit application Monitor 1 Gang Mount Box if required not supplied Surface mount the bracket of the monitor or if required onto a 1 gang mount box not supplied Make the system connections to the back of the monitor and then slide the monitor onto the bracket using the hooks to ho...

Page 5: ... Example 1 Dip switch 6 set to ON when device is at the end of system line Dip switch 7 set to OFF to select monitor as the Master Only one monitor on the system can be the Master APKITBLK Manual indd 5 26 04 2017 09 40 01 ...

Page 6: ...to ON END OF LINE 6 4 When using different style monitors on the same system please refer to supplied instruction to configure Master Slave and End of line position END OF LINE 6 System Connections Example 2 APKITBLK Manual indd 6 26 04 2017 09 40 02 ...

Page 7: ... both J3 and J2 positions 1 2 3 J1 J2 J3 NC 4 3 _ _ _ Electro magnetic lock Electronic lock BUS System Wiring LOCK1 VCC J1 Image of jumper link Lock release time N C for Electro magnetic lock N O for Electronic lock Lock Connections Example 1 APKITBLK Manual indd 7 26 04 2017 09 40 02 ...

Page 8: ...r 1 gives the option to set the release time 5 sec 3 sec The door station has a secondry switch LOCK2 options Please refer to the operation guide for release instructions 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 N O N C N O Volt free Volt free 12vDC300mA MAX 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 1 2 3 J1 J3 J2 Image of jumper link Image of jumper link Lock Connections Example 2 APKITBLK Manual indd 8 ...

Page 9: ...Adjustment for the intensity of colour Talking Volume Adjust the volume level of the monitor Press the Talk button to end call Press the Lock button to release lock and press Talk to end call Press the Gate button to release lock 2 and press Talk to end call The visitor presses the call button A chime will sound The visitor s image will appear on the monitor Press the Talk button and begin convers...

Page 10: ...s E Bench test the system if the issue cannot be found A The user instructions and operation of the monitor has been understood B That the lock is powered sufficiently C All system cabling is secured and properly connected D All system cabling is clear of breaks or short circuits E On the rear of the door station ensure the lock output is switching when activated by the monitor Master Slave Settin...