4–5
070-20000340-01 Rev A
C
H APTER
4. I
NSTA LLI NG
B
A SE
S
TATIO N
U
N ITS
Figure4-4
Sync Connections for Multiple BSUs
Connects
Alt Sync Out
on Alternate Master
to
Alt Sync In
on all
BSUs except Master
Connects
Main Sync Out
on Main Master
to
Main Sync In
on
all BSUs
50-ohm terminations
T connector
T connector
T connector
T connector
Coaxial Cable with
BNC Connectors
Coaxial Cable with
BNC Connectors
Alternate Sync Master
Main Sync Master