18
Operation/Use
Safety instructions
Keep children, disabled persons and animals away from the door.
Never reach into a moving door or moving parts.
Do not drive through the door until it has been fully opened.
There is a risk of persons being crushed or cut by the mechanism
or sharp edges of the door.
Opening the door
1
2
•
Press button (1) or handheld transmitter button (2) once.
•
If the button is pressed during the door OPEN movement,
the door stops.
•
It closes when pressed again.
Closing door
•
Press button (1) or handheld transmitter button (2) once.
•
If the button is pressed during the door CLOSE movement,
the door stops. Depending on DIP switch 7.
•
It opens when pressed again.
Emergency release
Caution!
The emergency release is only suitable for opening or closing
the door in an emergency.
E.g.: a power outage or operator failure. It is not suitable
for regularly opening or closing the door for other reasons.
This could cause damage to the operator or door.
Caution!
In an emergency release the door could independently open
or close itself due to a broken spring or incorrect setting
of the weight balancing.
The operator could be damaged or destroyed.
Important information!
It can be locked and released in any door position.
N
N
•
Pull the emergency release cord (N) once; the operator moves freely
and the door can be moved manually.
•
Pull the emergency release cord (N) once again; the operator locks
and the door can only be moved with the motor.
•
If there is a slip door installed in the door but no slip door safeguard –
install a slip door safeguard (see accessories instructions).
•
If the garage door does not have a built-in slip door or the garage does
not have a separate entrance, you must install an emergency release –
a release lock or Bowden cable – that can be operated from outside
(see accessories instructions).
Control unit reset
Important information!
After a control unit reset, the operator must
be reprogrammed.
2
4
3
1
•
Take off the rubber cover (1).
•
Press button (3) until the red LED (4) goes out.
•
LED off – force values deleted, release button (3).
•
Red LED (4)
fl
ashes – controller reset successful.
•
Reattach the rubber cover (1).
Intermediate stop
An intermediate stop, caused by actuating a button or handheld transmitter,
immediately stops the operator. At the next command the operator moves
in the opposite direction, see “Pulse sequence of door movement”.
Safety stop 1 (power cut-off)
For a power cut-off, the operator stops or reverses.
At the next command the operator moves in the opposite direction,
see “Pulse sequence of door movement”.
– Safety stop when closing the door – the door reverses
– Safety stop when opening the door – the door stops
Safety stop 2 (safety input)
When the safety input is triggered (e.g. if someone has gone across
the photo eyes), the operator stops, reverses or opens depending
on the setting of DIP switches 1 + 3.
See chapter “Obstacle detection” for the relevant operator types.
At the next command the operator moves in the opposite direction,
see “Pulse sequence of door movement”.
Factory settings:
– Triggers the safety input while
– door is closing – door reverses
– Triggers the safety input while door is opening
– No reaction (door opens)
Overload protection
If the operator is overloaded during opening or closing, the control system
detects it and stops the drive. After about 20 seconds or a control unit reset,
the control unit releases the overload protection again.
The operator can now resume operation.