Freestanding:
The Inset Electric Fire can be placed in any location as a free-standing unit, as long as
the Inset Electric Fire is kept approximately I MT clear from any combustible objects.
Securing the Inset Electric Fire to a Fire Chamber Based on Minimum Dimensions
STEP I: Ensure
that the Inset Electric Fire is switched off and unplugged from the mains
power supply.
STEP 2:
Remove the four screws from the back of the removable fascia and then pull h:
up and away from the Inset Electric Fire main unit
STEP 3:
Using a pencil, mark the centre of the opening in which the Inset Electric
Fire will fit from this point, measure 215.5 mm to the left and then again to the
right, marking the points. Measure 560 mm from the floor up and mark this final
point.
STEP 4:
Drill where the holes have been marked and insert the two screws, leaving a 2
mm gap.
STEP 5:
Carefully lift the Inset Electric Fire, hook it onto the screws and lower it into
position.