20
•
The following describe in detail the recommended items to be checked, whether
it is a daily check (every 8 hours) or a weekly check (every 40 hours).
Once the Pre-Operation Walk-Around is complete a final inspection should be done by
operating the applicator for a short period of time. Stop the unit and check the gauges
and display screen.
Daily Pre-Operation Checklist
Before operating the applicator it is important to inspect the following items for safety
and performance.
CHECK EVERY 8 HOURS (DAILY)
1. Refill Fuel
2. Check engine oil level
3. Check engine coolant level
4. Check hydraulic fluid level
5. Check fuel/ water separator
6. Verify that all lighting is in working order
7. Inspect that all railings are in place and secure
8. Inspect that all safety guards are in place
9. Inspect that the mixing tank is free from foreign objects
CHECK EVERY 40 HOURS (WEEKLY)
1. All Safety Decals
2. Safety Surfaces for wear
3. Check Hydraulic Hoses for any wear
4. Check engine air filter for clogs and debris
Re-Filling Fuel
Always use fresh diesel fuel when re-fueling the XA1200 Applicator. The fuel tank is
sized to allow for continuous work for 8 hours between fill-ups. The fuel tank fill is
located on the front of the unit, on the right side. The sight gauge is located on the side
of the fuel tank.
Fuel fill
Summary of Contents for XA1200