37
Hose Work With Radio Transmitter (if equipped)
1. Close the recirculation valve. If using an extension hose connected to a discharge
boom, open the discharge valve. If using the hose reel, close the discharge valve
and open the valve to the hose reel.
2. Turn the remote transmitter ON.
3. When the operator is in position, turn on the pump using the remote transmitter
and increase the pump speed to the desire output.
To quickly shut off the engine at any time, press the red E-Stop Button on the
transmitter. To restart the engine, return the key switch on the control panel to
the OFF Position.
8. When finished spraying, turn the pump off.
When using the radio remote control option, the secondary operator(s) must be
aware that the machine can be remotely activated at any time. If any maintenance
or troubleshooting needs to be performed while the engine is running, the Remote
On/Off switch must be in the OFF position. Failure to comply could result in
minor personal injury or product or property damage.
Reloading Procedure
1. Follow steps 1-9 for in the “Purge and Clean” on page - of this manual.
2. Follow steps for “Mixing Material” on page – of this manual.
3. After the last load of the day, fill the tank with sufficient water to rinse the inner tank
walls. Purge the discharge plumbing with water to remove the mulch materials from
the pipes. If hose work was undertaken- rinse the interior of the hose as well.
CLEANING AND MAINTENANCE
DAILY - CLEANING THE APPLICATOR
Hydroseed material can produce gases that are
harmful or deadly if inhaled. Empty the slurry tank
daily to prevent build-up of these gases.
Do not store material for long periods of time in
the slurry tank. Harmful or deadly gases could
result.
1. Fill the slurry tank to the center of the agitator shaft with clean water.
Summary of Contents for XA1200