48
SUPER
AIRFLOW CONVERTER
SUPER
AIRFLOW CONVERTER
Out
1/2
In
1
Out
Add
Setting the sensor output calculation method (3)
●
General vehicles using 2 airflow sensors
When the product is used with two airflow sensors and an
ECU with single airflow sensor control.
In
2
※
Because of a single engine control
unit input, the measured air
volume of the 2 airflow sensors is
added (Add) and its result is output.
※
In this case, airflow sensor 1 measures an air
volume of 4 and airflow sensor 2 measures an
air volume of 6.
Setting the sensor output calculation method (4)
●
Skyline GT-R using an airflow sensor
When the product is used with an airflow sensor and an
ECU with twin airflow sensor control.
ECU
ECU
※
Because of 2 airflow sensors
Measured air volume
4
Measured air volume
6
Input air volume
10
Output air volume
10
Airflow
sensor
1
Airflow
sensor
2
※
Because of a single airflow sensor
Measured air volume
10
Airflow
sensor
Input air volume
10
Output air volume
5
Output air volume
5
※
Because of two engine control
unit inputs, the measured air
volume of the airflow sensor is
divided into halves and its result
is output.
※
In this case, the airflow
sensor measures an air
volume of 10.