background image

Page 6

Page  7

The COMP 500 module is an optical compressor. It features an elec-

tronically balanced input and uses a Jensen JT-11DL nickel output 

balancing transformer. The optocoupler was designed to be as fast 

as possible and is produced exclusively for Aphex.  The COMP 500 

also features stereo linking.

2.0 INTRODUCTION

3.0 CONTROLS & INDICATORS

3.1 DRIVE CONTROL

The Drive control determines the amount 

of input signal sent to the compressor.  The 

COMP 500 has a maximum input level of 

+27dB.  Turning this knob clockwise will 

result in more gain reduction.  However, the 

total amount of gain reduction is determined 

by the Ratio control.

3.2 RATIO CONTROL

The Ratio control determines how hard the 
input signal is compressed.  It has a range of 
1.5:1 to 10:1.  This means that with the knob 
set fully clockwise, for every 10dB of input 
signal only 1dB of signal is sent to the output.  

3.3 GAIN REDUCTION METER

The 10-segment Gain Reduction meter pro-
vides visual feedback as to the amount of 
gain reduction measured in dB.  The example 
above would register about 12dB of gain 
reduction.

3.4 RELEASE CONTROL  

The Release control determines the amount 
of time it takes for the audio signal to return 
to normal levels after the signal is no longer 
being compressed.  Use a slower setting for a 
leveling affect when inserting the COMP 500 
on a buss.  A faster setting would be more 
appropriate for compressing a dynamic signal 
like a vocal or kick drum.  

• 

Transparency in the behavior of the optical

   element.

• 

Flexibility of being able to control the

   release time from a leveling amp behavior

  to a compression behavior.

• 

Character of the Jensen output transformer.

• 

The combination of these features makes

   the COMP 500 unique.

Summary of Contents for COMP 500

Page 1: ...Owner s Manual COMP 500 OPTICAL COMPRESSOR 500 SERIES MODULE ...

Page 2: ...the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help CAUTION For continued protection against risk of fire replace only with the same type and rating of fuse ATTENTION pour une protection continue contre les risques d incendie ne remplacer qu avec la même valeur et même type de fusible W...

Page 3: ...00 module into place until it is positively seated in the card slot 5 Use the 2 thumb screws in the module to mount the COMP 500 front panel to the 500 series rack These screws have a pretty tight fit please be careful not to cross thread 6 Plug your 500 series rack back into the AC source and power up your rack Your COMP 500 will automatically power up with your 500 series rack TABLE OF CONTENTS ...

Page 4: ...0 1 This means that with the knob set fully clockwise for every 10dB of input signal only 1dB of signal is sent to the output 3 3 GAIN REDUCTION METER The 10 segment Gain Reduction meter pro vides visual feedback as to the amount of gain reduction measured in dB The example above would register about 12dB of gain reduction 3 4 RELEASE CONTROL The Release control determines the amount of time it ta...

Page 5: ...ack that is too fast can change the natural character of an instrument while too slow can lose the benefits of compression The COMP 500s interactive attack adapts to the input signal controlling volume without changing character and enhancing punch while retaining articulation Typically compression creates more sustain by raising the level as the sound decays This is more or less apparent dependin...

Page 6: ...aced modified or removed c Damage or deterioration 1 Resulting from installation and or removal of the unit 2 Resulting from accident misuse abuse neglect unauthorized product modification or failure to follow instructions contained in the User s Manual 3 Resulting from repair or attempted repair by anyone not authorized by Aphex 4 Occurring from shipping claims must be presented to shipper WHO IS...

Page 7: ...ment and send it to APHEX 3500 N San Fernando Blvd Burbank CA 91505 USA PH 818 767 2929 FAX 818 767 2641 INPUT Type Impedance CMRR Max Input Level comp off Max Input Level comp on OUTPUT Type Impedance Nominal Operating Level Maximum Level Level Meter Peak AUDIO Frequency Response THD THD POWER Current draw OPERATING LEVEL Switch Setting 4dBu Transformerless active balanced 40kohm balanced 20kohm ...