background image

 
 

 

Note 1: 

Ensure SIM cards operating temperature range from telecom service provider. 

 
 

WARNINGS 

 

Warranty is voided if case is damaged. 

 

A9  IPEX  device  and  all  peripherals  must  be  powerless  during  the  installation. Turn  off  ignition  and 
disconnect power. 

 

GPRS may interfere sensitive electronics. 

 

All devices connected to A9 IPEX device must have a fuse protection. 

 

All signal inputs connected to A9 IPEX must be fuse protected, max 3A. 

 

As a rule, when pulling Aplicom cables through inlets or tubes during installation, it is not allowed to 
pull directly from connectors. Instead the pull must be directed to cable itself.  

 

Do not install unit in places were safety may be compromised. 

 

Ensure CAN connection and limitations from vehicle manufacturer or dealer. 

 

For replacing the internal battery see document 

K520016 A9 IPEX

 

battery replacement guide

 

available on Aplicom extranet. DO NOT USE OTHER BATTERIES THAN APLICOM DELIVERED. 
RISK OF EXPLOSION.   

 

DISCONNECT ALL CABLES FROM A9 IPEX connectors before changing internal battery.

 

 

FCC compliance information 

For products using SDoCa compliance information statement shall be supplied with the product at the time of 
marketing or importation, containing the following information: 
a) Identification of the product, e.g., name and model number; 
b) A statement that the product complies with the rules; and 
c) The identification, by name, address, and telephone number, or internet contact information, of the 
responsible part. 
 

§

2.1077 (a)(3) The identification, by name, address and telephone number or Internet contact information, of 

the responsible party, as defined in §2.909. The responsible party for Supplier's Declaration of Conformity 
must be located within the United States. 
 
For FCC Part 15 devices §15.19(a)(3): 
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference and  
(2) this device must accept any interference received, including interference that may cause undesired 
operation. 
 
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The 
End user must follow the specific operating instructions for satisfying RF exposure compliance. This 
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.Changes 

TECHNICAL DATA 

 
 

 

 

Supply voltage 

6,8…32Vdc (n12Vdc) 

Dimensions 

92mm (W) x 151mm (L) x 46mm (H) 

Current consumption 

Typical: < 100mA 
Max (peak): 1A / < 1s 

Weight 

250g + cable 150g 

GPS antenna power 
supply 

3Vdc 

Housing / material 

IP67, PC + 10%GF 
 

Fuse 

External fuse on power cable: 3A  
Internal fuse: 3A/slow 

User interface 

SIM card slot (inside the unit) 
Indicators (LED): 
Led - JAVA appl.(inside the unit)  

Operating temperature 

-30

C...+70

C (see 

Note 1

-5

C...+60

C With internal battery 

 0

C...+45

C internal battery charge 

Options 

CAN option 

Storage temperature 

-40

C...+80

Warranty 

1 year 

Relative humidity 

+95% max 

 

 

Power switch           

None, IGN and SW controlled 

 

CE marking/Approvals 

 

according to directives: 
2004/108/EC 
1999/05/EC 
ECE r.10.05 E-type approval 

Common connections 

Internal GSM /GPRS antenna   
Internal GPS/GLONASS antenna 
 

 

 

  

Summary of Contents for A9 IPEX

Page 1: ...ports following device A9 IPEX Document code K520010 Important Please read this installation guide before the installation Aplicom Oy P O Box 33 FI 44101 Äänekoski Finland Telephone 358 10 841 9414 Business ID 0995791 7 Äänekoski Info aplicom fi www aplicom com ...

Page 2: ...Therefore we reserve the right to make changes and improvements to any of the products described in this guide without prior notice Due to these improvements the contents of this manual are subject to change without notice Aplicom Oy is not responsible for any loss of data income or any consequential damage This crossed out wheelie bin means that within the European Union the product must be taken...

Page 3: ...t by using A9 NEX TRIX data cable D337055 Figure 4 6 Close the unit and tight up four cover screws Avoid extreme torque 0 8 1 0 Nm Refer to Figure 5 on how to install the top cover correctly Please follow this instruction because otherwise there is risk that the antenna connector will broke 7 Connect external power cabling and other needed connections 8 Mechanically install the unit to carefully s...

Page 4: ...larly with remaining two corners Mechanical Installation Note that the unit includes internal GPRS and GPS antennas and shouldn t be installed in metal cage Because of the internal GPS GLONASS antenna install unit to place where unit s top cover has the best possible open sky view ...

Page 5: ...ection could break down Electrical Installation Read warnings chapter on page 7 on this document Protect power supply lines 6 8 32Vdc with 3A fuse at power supply end of line Install the A9 IPEX unit as far away as possible minimum 1 metres recommended from the car radio and its antenna or other electrical devices to avoid any interference Additional information Application note K505002 Cabling of...

Page 6: ...ered and wire nr 1 is connected to screw connector position 1 as default and wire 2 is connected to position 2 and so on The used cable has seven wires Figure 8 1 GND 2 PWR 3 IGN DIN1 4 DIN2 5 OC 6 CANH 7 CANL Used to SW configuration COM1 port sw option and SW debug Note Use only Aplicom specific cable Note When using this cable the unit has to be open top cover removed Testing installation If th...

Page 7: ... 2 1077 a 3 The identification by name address and telephone number or Internet contact information of the responsible party as defined in 2 909 The responsible party for Supplier s Declaration of Conformity must be located within the United States For FCC Part 15 devices 15 19 a 3 This device complies with Part 15 of FCC rules Operation is subject to the following two conditions 1 this device may...

Page 8: ...empt RSS s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment For Canada ICES RSS L émetteur réce...

Page 9: ...PEX right orientation towards the GPS GLONASS satellites and correct fixing place and surface POWER ON DEVICE Connect PWR and if IGN is used turn it on FINAL CHECK Before completing the installation work rigorous checking of any disturbances to vehicle or machine where the unit is installed must be made Special attention is needed to check the vehicle safety systems and radio and multimedia equipm...

Page 10: ... the nut taking care that seal is firmly located under the gland Note All metal grit has to be removed from the housing using compressed air after the installation Mount the cable to the gland so that outer jacket of the cable can be seen inside the housing refer to the picture left Install remaining parts of the cable gland assembly to the cable refer to the picture left ...

Page 11: ...use the threadlocker in the thread of the cable gland to secure the assembly Suitable threadlocker type is medium strength type like Würth 0893243050 or equivalent Tighten the nut with the help of the suitable feeler gauge which thickness depends on used interface cable For standard IPEX cable the thickness of the feeler gauge is 2mm Make sure that feeler gauge is removable after tightening the nu...

Reviews: