Page 24 of 60
F4
Slide Solderting Condition Entry Screen
When you press VIEW when entering Soldering condition number, the following Soldering
condition entry display appears.
Select the each condition that is necessary to the point where you did Teaching by CURSOR key,
then press ENTER
→
Input value
→
ENTER for register.
After entering necessary value, the screen returns to Soldering condition number input screen by
ESC key.
Press ENTER.
Enter the line speed and press ENTER.
“Start of Line Soldering” point has been registered and the
next point screen is displayed.
*Soldering condition can be also entered in “Soldering condition” by pressing MENU key at
Teaching mode.
Soldering Condition 1 1/2
Soldering Type Line Soldering
1st Amount 7mm
1st Feed Speed 15mm/s
1st Rev. Amount 3mm
1st Rev. Speed 50mm/s
Pre-Heat Time 0.5sec
2nd Amount 1 10mm
2nd Feed Speed 1 15mm/s
2nd Amount 2 0mm
2nd Feed Speed 2 15mm/s
2nd Amount 3 0mm
2nd Feed Speed 3 15mm/s
Soldering Condition 1 2/2
2nd Amount 4 0mm
2nd Feed Speed 4 15mm/s
Start Pool Time 0sec
2nd Rev. Amount 3mm
2nd Rev. Speed 50mm/s
Heating Time 0sec
Enter a number
Condition Number 1
DEL COPY NEW LIST VIEW
Program1
P2
X 0mm
Y 0mm
Z 0mm
R
0deg
FUNC JOG MDI
INIT
Enter a number
Line Speed 10 mm/s
*Slide soldering requires to synchronize the axis moving and
solder feed speed.
Calculating formula:
Absolute distance between 2 points
(End of slide soldering coordinate – Star of slide soldering coordinate)
Line Speed
2nd solder feed amount
2nd solder feed speed
Right side and left side need to be same value.
=