19.
Soldering System Settings
19.1 Iron Shot Counter
When the present value of the counter reaches the set iron shot counter, the message on teaching
pendant appears and a buzzer sounds. This is useful function to exchange iron tip.
*Factory setting: “Enable”
Press MENU key at teaching mode, and select “Soldering
System Settings”.
Then, select “Iron Shot Counter” and press ENTER .
Select “Enable” and press ENTER .
Select “Iron Shot Counter SV” and press ENTER ..
Enter the maximum setting value.
*The maximum set value:99999
*The maximum count value:99999
Soldering System Settings
Enter a number
Iron Shot Counter 10000
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s
Iron Shot Counter
Disable
Enable
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Iron Shot Counter SV 10000
Iron Shot Counter Reset 102
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s