Page 48 of 60
19.6
Feeder Calibration
The solder wire feed/ reverse amount can be adjusted.
When the solder diameter is changed, the balance between setting amount and measured amount
can be calibrated. *Initial value: 100%
Press MENU key at teaching mode, and select “Soldering
System Settings”.
Then, select “Feeder Calibration” and press ENTER .
Enter the calibration value (1~200%).
*Initial value: 100%
It calibrates the feeding and reversing amount.
Less than setting amount: 100% < 200%
More than setting amount: 1% < 100%
*When the calibration value is changed, save the data.
Then in order to reflect the calibration value, turn the power off and turn it on again, or switch to
operation mode.
19.7 Manual Feed Speed
The manual feeding speed can be adjusted.
The reverse speed is fixed at 50mm/sec.
*Initial value: 50mm/sec
Press MENU key at texching mode, and select “Soldering
System Settings”.
Then, select “Manual Feed Speed” and press ENTER .
Enter the speed value.
Setting range is 1mm/sec ~ 50mm/sec.
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed 50mm/s
Soldering System Settings
Enter a number
Feeder Calibration 100%
Soldering System Settings
IO Function Assignment
Iron Shot Counter Disable
Cycle Count Disable
One Touch Feed Length 0mm
APN05 Alarm Display Disable
Type of Restart Program End
Type of Error Reset START BUTTON
Feeder Calibration 100%
Manual Feed Speed
50mm/s
Soldering System Settings
Enter a number
Manual Feed Speed 50mm/s
e.g)
When the feeding amount is set in 100mm, the measured value is 90mm.
Feeding amount
÷
Measured amount = Calibration value (Convert to % , per 1%)
100mm
÷
90mm = 1.11….
→
Calibration value is 111%