Page 50 of 60
I/O-1
Name
Description
Pin No.
Input
#gen In 1
Solder Shortage
1
#gen In 2
Solder Clogged
2
#gen In 3
Temperature error
3
#gen In 4
Upper Limit Sensor
4
#gen In 5
Lower Limit Sensor
5
#gen In 6
Free
6
#gen In 7
Free
7
#gen In 8
Free
8
Output
#gen Out 1
Solder Feed
9, 10
#gen Out 2
Soldering Reverse
11, 12
#gen Out 3
Free
13, 14
#gen Out 4
Free
15, 16
#gen Out 5
Iron U/D
17
#gen Out 6
Solder Feed (Line)
18
#gen Out 7
Air Blow
19
#gen Out 8
EMERGENCY
20
Others
COM +
DC24V
21
COM +
DC24V
22
COM -
GND
23
COM -
GND
24
How to change I/O SYS Function Assignment
It is possible to change the I/O SYS function assignment of the previous page.
The leftmost descriptions are the initial setting for each signal.
In order to change the I/O SYS function,
Press MENU key in the Teaching Mode
Run Mode Parameter
I/O Settings
Then change the I/O SYS funciton.
If impossible, assign a variable (mv, mkv, etc.) of the “I/O-SYS Funcition Assignment” in the
“Teaching Mode Menu”. Then, change again the I/O SYS function in the “I/O Settings” of “Run
Mode Parameter”.