21. Error sign
The list below is the error sign on the teaching pendant.
Error display
Description
Failure reason
Recommend solution
SOLDER
SHORTAGE
Detection of solder
shortage sensor
End of solder wire
feeding
Replace with a new solder wire.
5. Preparation
Breaking of solder
wire.
Remove the solder in solder tube and
reset solder wire.
5. Preparation
Misdetection
of
solder
shortage
sensor
Check solder wire is set properly.
5. Preparation
Soldert
shortage
sensor is damaged.
Contact Apollo Seiko or our agency for
repair.
SOLDER
CLOGGED
Detection of solder
clogged sensor
Solder
wire
is
clogged in solder
tube.
Replace a new solder tube.
5. Preparation
Solder wire does not
melt properly.
Slow down the speed of solder feeding.
17. Initial Value of Soldering
Condition
Adjust the position of solder feeding.
5. Preparation
HEATER ERROR
Error detection of
temperature
controller
The iron cartridge is
not
inserted
properly.
Check the iron cartridge is set properly.
26. How To Change Iron Cartridge
Breaking of iron tip
heater
Replace new iron cartridge.
26. How To Change Iron Cartridge
Thermocouple
is
damaged.
The range between
temperature alarm
upper value and
lower value is small.
Enter proper value in the system
parameter.
6. How To Set Temperature
Controller
COMET
NOT
READY
COMET
is
not
ready properly.
Power
is
not
supplied.
Turn on the power.
If the power is not supplied, contact to
Apollo Seiko or our agency.
4. Description
Unit error
Turn off and on the unit power switch.
4. Description
COMET
COMMUNICATION
ERROR
Communication
error of the robot
and COMET
RS-232C cable is
disconnected.
Check the RS-232C cable.
4. Description
Unit error
Turn off and on the unit power switch.
If the error is not resolved, contact to
Apollo Seiko or our agency.
4. Description
Mismatch
of
soldering condition
data etc.
The parameter is not
entered properly.
Check the parameter of soldering
condition.
11.~14. Program setting
FEEDER
COMMUNICATION
ERROR
Communication
error of COMET
and feeder
Feeder cable is not
disconnected.
Connect feeder cable.
4. Description
Unit error
Turn off and on the unit power switch.
If the power is not turned on, contact to
Apollo Seiko or our agency
4. Description