Serial Interface Specifications
64
Apollo GX50/60/65 Installation Manual
Example Fuel / Airdata Input Data
<STX>SA223
223 knots indicated air speed
SB230
230 knots true air speed
SC101
0.101 mach
SD+3200
32,000 feet pressure altitude
SE+3312
33,120 feet density altitude
SF+05
+5°C outside air temp
SG-03
-3°C true air temp
SH010
wind direction at 10° (relative to true north)
SI015
wind speed at 15 knots
SJ+03
+3° / second right turn
SK-050
-50 feet / second vertical air speed
SL359
359° heading (relative to true north)
SM0123
12.3 gallons / hour - right engine fuel flow
SN0300
30.0 gallons used - right engine
SO0131
13.1 gallons / hour - left engine fuel flow
SP0310
31.0 gallons used - left engine
SQ000
no errors
S*123
Checksum (example only, not actual)
<ETX>
end of message string
Figure 21 Fuel / Airdata Data Input