background image

SRTM

Instruction Manual  

SRTM LED display DIN Rail Transducer 

35

75

37.5

119.5

1

3

2

4

5

7

6

8

Attention:pleasse subject to the diagram on the product if any changes.

1

3

2

4

5

7

6

8

DC voltage/current  

OutPut

IntPut

1

3

2

4

5

7

6

8

AC voltage/current 

OutPut

IntPut

H

L

1

3

2

4

5

7

6

8

PT100

OutPut

1

3

2

4

5

7

6

8

TC

OutPut

IntPut

IntPut

1

3

2

4

5

7

6

8

★ ★

★ ★

SRTM

AA

Type        power               analogue        input signal          range

I1

I2

0-10V

AC Curent    
AC voltage   
DC current     
DC voltage     
Tc  thermocouple    
RTD  

Example: AA5 or AV600.

90-260V AC/DC
(default) 

SRTM

AV
DA
DV
Tc

RTD

Return PVF 

Input Low value

Input low value setting  
range:-1999-9999

Decimal  point

Analogue output low value

Analogue low limit setting  
range:-1999-9999

Analogue output High value

Analogue High limit setting  
range:-1999-9999

Size(units:mm)

Please do not turn on the power supply until all of the wiring is completed.
Otherwise electrical shock, fire or malfunction may result.

Do not wire when the power is on. Do not connect the unused terminals.

 Do not turn on the power supply when cleaning this instrument. Do not disassemble,

repair or modify the instrument. This may cause electrical shock, fire or malfunction

Us e t his ins tru men t i n t he scop e o f i ts specifications.

 Otherwise fire or malfunction may result.

This instrument should be installed in a domestic environment. Otherwise electrical shock, fire or

malfunction may result. The operating temperature environment should between 0 (32F) to 50 (122F).

To avoid using this instrument in environment full of dust or caustic gas.
To avoid using this instrument in environment of strong shock or concussion.

To avoid using this instrument in environment of overflow water or explosive oil.

Caution

Warning

Output should start in about 10 seconds after power on when the instrument

has control output function.

Models

Name of parts

Function

Mark

Names  

output lamp

indication lamp 

indication lamp  

indication lamp  
parameter select

/confirm Key 
move key 

Up Key

Down Key  

output lamp

Resistance/ temperature lamp,ON:diaplay Ω,flash:℃

Voltage lamp  ON:display V, flash:mV

Current lamp   ON: display A,flash:mA

Star or stop parameter setting,change model key

Move key/clear key/RST key

 Parameter Up Key

Parameter Down Key

Connection Drawing

Parameter setting

Power ON

Self-check and LED ON

Display measure Low value

Display measure High value

Display measuring value

Modification value,display 
value=measure value
-PVF   range±50.0

Measure modification value 

Parameter setting menu

Input signal

Input signal by select

It  means

Input High value

Input High value setting  
range:-1999-9999

Decimal point by select:
0.000、00.00、000.0、0000

Parameter  lock

Lock value:range 0-255    
LCK=000 can amend it. 
LCK=010 only read it.

Reviews: