ASSEMBLY INSTRUCTIONS
For installation by a qualified electrician in accordance with national and local electrical codes
and the following instruction. The suitability of this type of termination must be evaluated by
Underwriter's Laboratories, Inc. and Canadian Standard Association for the end use application.
Assemble contact to the cables according to the equipment manufacturer's assembly instructions.
The following instructions are supplied as a reference.
Please note:
Instructions are included with each crimp tool for terminating specific contacts. Use of
non-Anderson Power crimp can effect UL & CSA Approval.
1. Strip cable to dimensions in Table A.
2. *Crimp or solder contact to cable following Tables B, C and D.
3. Observing proper polarity, place contact in housing with notched side of tongue next to spring.
(see cross section above).
4. Push contact and cable into housing until it snaps over end of spring; tug slightly to make sure
contact is locked into place.
* Soldering recommended for cables with solid or minimal conductor stranding
(ex. THHN type wire).
Table A:
Cable Stripping Dimensions
Table B: Recommended Soldering Techniques
Recommended Soldering Techniques
Use rosin flux solder only. Wrap cable strands. Melt solder into well, heat and insert stripped
cable. Continue heating well until solder flows into wire, being careful not to over flow onto
contact surface. Do not solder-dip contacts. Cable clamps for solder connections to
unsupported leads (required by Underwriter's Laboratories, Inc.) are listed on Table E (over).
SBS™ Connector
Assembly Instructions
Connector
"X"
"X"
Series
inches mm
SBS™50
9/16
14
X
Tw o P o l e C o n n e c t o r s w i t h S i n g l e - p i e c e H o u s i n g s
• Insulated housing • Stainless steel springs
• Silver plated contacts • Finger proof