6. INSTALLATION INTO FACTORY-BUILT
CHIMNEY
NOTE: Use of aluminum type 13 gas vent for solid
fuel is unsafe and prohibited by the National Fire
Protection Association Code.
After the stove is positioned, suspend a plumb bob
over the center of the damper opening to determine
the chimney penetration point.
The Model 36-BW stove must be connected ONLY to
a UL listed class A all fuel burning heating appliance
chimney. CAUTION: SOME CHIMNEYS ARE
AVAILABLE WITH A UL LISTING THAT ARE NOT
CLASS A AND ARE NOT SAFE FOR USE WITH A
SOLID FUEL APPLIANCE.
Install the chimney following the manufacturer’s
instructions exactly. DO NOT DEVIATE FROM
THESE INSTRUCTIONS!
The chimney should extend a minimum of 3 feet from
the roof structure or 2 feet higher than the highest
point within 10, whichever is greater. This assures
proper chimney function and reduces the possibility of
back drafts.
NOTE: All installations must meet local building and
fire codes. Check with local building officials for
assistance in getting permits, inspections and good
advice.
7. IMPORTANCE OF PROPER DRAFT
Draft is the force that moves air from the appliance up
through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local
geography, nearby obstructions, and other factors. Too
much draft may lead to excessive temperatures in the
appliance and may damage the catalytic combustors.
Inadequate draft may cause backpuffing into the room
and “plugging” of the chimney catalyst.
NOTE: An uncontrollable burn or a glowing red stove
part or chimney connector indicates excessive draft.
FIGURE 9
INSTALLATION INTO FACTORY-BUILT CHIMNEY