The power key does not power on
Stratus ESG
1.
Verify that the power key is not stuck.
2.
Verify that the circuit breaker has not tripped.
If it has tripped
: Reset the circuit breaker
switch try the power key again.
NOTE
: If the circuit breaker opens it may be
reset only once.
If it did not trip
: Verify that the electrical
connection to the transponder is secure. Verify
that the voltage at the input to the unit is
between 11 VDC and 36 VDC.
The altitude displayed is incorrect
1.
Enter into configuration mode on Stratus ESG
and verify that the altitude source is set as the
currently used altitude source. If the altitude
source is a serial connection, verify that the
correct encoding option was selected.
2.
Verify that the correct connections are made to
the transponder.
3.
Use an altitude simulator to verify the cabling.
4.
Verify that there is not a problem with the
altitude source.