AA System Operation Manual
Page 4 of 27
© 2007
SYSTEM SPECIFICATIONS
Electrical
Model HZ
Motor
HP
Volts
Phase
AA-12514-116 60
1/3
115/230
1
AA-12514-215/6
60 or 50
1/3
220/230
1
AA-12521-116 60
1/3
115/230
1
AA-12521-215/6
60 or 50
1/3
220/230
1
AA-32514-116 60
1/3
115/230
1
AA-32514-215/6
60 or 50
1/3
220/230
1
AA-22521-116 60
1/3
115/230
1
AA-22521-215/6
60 or 50
1/3
220/230
1
NOTES:
1. All systems rated at 77 Degrees Fahrenheit (25 Degrees Celsius) using 1000 ppm sodium
chloride (NaCl) solution. System capacity decreases significantly with decrease in feed
water temperature (see temperature correction chart).
2. Chlorine requirements for the feed water are as follows:
Thin-Film (standard)
0 ppm
CA (special order only)
0.1 ppm Minimum
3. Feed water must be filtered to a turbidity of less than 1 NTU.
4. System recovery (permeate to concentrate ratio) must be maintained at the recommended
level. A higher than recommended recovery will lead to a premature fouling of the
membrane with a loss of permeate flow and permeate quality.
5. Softened water should be used for the feed water to the RO system.