Installation and Service Manual – Metered Carbon Filter
Page 13
Copyright © 2012 Applied Membranes, Inc. All Rights Reserved.
Configuration Settings
(Pre-Programmed to Factory Defaults)
Step 1CS
Press
▲
and
▼
simultaneously for 5 seconds and release. If screen in Step 2CS does
not appear, the lock on the valve is activated. To unlock press
▼
, NEXT, REGEN,
▲
in
sequence, then press
▲
and
▼
simultaneously for 5 seconds and release.
Step 2CS
Press
▲
or
▼
to select
1.5
(for 1.5” valve). Press NEXT to go to Step 3CS.
Press REGEN to exit Configuration Settings.
If 2.0 or 2.0L are accidentally selected, an additional screen will appear. If selected,
press REGEN to return to this step and set to 1.5
Step 3CS
Select "Volume” arrow (with a blank number display). If a different display (listed below)
is shown, press the
▲
or
▼
buttons to scroll through the options until the correct display is
shown. When Volume (gallons) is selected the regeneration will occur after the specific
volume has been used or on the day override (if selected) whichever comes first.
Step 4CS
Press
▲
or
▼
to select “DELY”
Press NEXT to go to Step 5CS. Press REGEN to return to previous step.
Step 5CS
Press
▲
or
▼
to select “OFF” option.
Note: If a setup utilizing a No Hard water Bypass (purchased separately) or “Separate
Source” during regeneration choose the appropriate option in this step. Detailed
instructions follow.
Press NEXT to go to Step 6CS. Press REGEN to return to previous step.
If “ALT” is accidentally selected in step 5CS, an additional screen for Rinse & Fill delay
will be displayed. If this is selected, press REGEN to return to the previous step and set
to “OFF”.
Step 6CS
Press
▲
or
▼
to set external pressure differential option the desired setting:
“oFF” should be selected if no dP switch is connected
If dP is connected choose from “on0”, “dELy”, or “HoLd”.
See detailed instructions on the following page.
Press NEXT to exit configuration settings. Press REGEN to return to previous step.
Configuring the Control Valve for No Hard Water Bypass Operation
No Hard Water Bypass equipment is sold separately. Only use no hard water bypass
valves supplied by the manufacturer of this product which are specifically design for use
with this valve. Select nHbP for control operation. For no hard water bypass operation, the
three wire connector is not used.
Selection requires that a connection to the No Hard Water Bypass Valve is made to the two pin connector labeled
ALTERNATOR DRIVE located on the printed circuit board.
Note: If the control valve enters into an error state during regeneration mode, the no hard water bypass will remain in its current state
until the error is corrected and reset.