126
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-42 (EU)
Denominator of electronic gearing
ratio
Data Range
Default
Unit
LED Display
1 - 1000
1000
1000(Note)
Defines the denominator of electronic gearing ratio. Refer to Section 7.2.5 Electronic Gearing Ratio
NOTE:
1.
For firmware 1.00K or lower, if you need to view or set this value on the drive’s control panel, refer to the following calculation:
LED
display
value
=
V x 32
Where
V
is electronic gearing ratios, units counts.
2.
For Firmware 1.00L or above, no calculation is needed
P-43 (SZ)
Input Pulse Setting
Data Range
Default
Unit
LED Display
0 - 65535
1792
1792
Pulse counter configuration and digital filter parameters in digital position control mode.
Bit0 - bit1: pulse type
Input Noise Filter
Higher 8 Bits
Lower 8 Bits
Pulse Polarity
Pulse Type
0 = STEP/DIR
1 = CW/CCW
2 = A/B quadrature
bit2: count direction
Bit8 - bit15: digital filter parameter
Refer to Section 7.2.2 Input Pulse Type and Input Noise Filter
P-44 (PF)
Position Fault limit
Data Range
Default
Unit
LED Display
0, 10 - 32000
20000
20000
The position fault limit in encoder counts. This value defines the limit threshold, in encoder counts, reached between the actual
position and the commanded position before the system produces a position
fault error. The drive’s LED display, will read
if a position limit fault occurs.
P-45 (PL)
Dynamical Position Error Range
Data Range
Default
Unit
LED Display
0 - 32000
10
10
Define the usage of input X10 as inhibiting the pulse input.
PI1: Inhibit the pulse input when input X10 is closed.
PI2: Inhibit the pulse input when input X10 is open.
PI3: Input X10 is used as general purpose input.