81
SV200 DC Hardware Manual
920-0126A
4/14/2017
7.2.2.3 Parameter P-43 (SZ) Setting
Parameter P-43 (SZ)’s higher 8 digits and lower 8 digits set the definition for input filter frequency and pulse type, the setting values are as
shown in table below:
Filter
Frequency
pulse type
CW/CCW
condition
P-43 (SZ)
setting value
Filter
Frequency
pulse type
CW/CCW
condition
P-43 (SZ)
setting value
100K
Step &
Direction
X2 on
25344
500K
Step &
Direction
X2 on
4864
X2 Off
25348
X2 Off
4868
CW/CCW
Pulse On X1
25345
CW/CCW
Pulse On X1
4865
Pulse On X2
25349
Pulse On X2
4869
A/B
Quadrature
X1 Leads X2
25346
A/B
Quadrature
X1 Leads X2
4866
X2 Leads X1
25350
X2 Leads X1
4870
150K
Step &
Direction
X2 on
16640
750K
Step &
Direction
X2 on
3072
X2 Off
16644
X2 Off
3076
CW/CCW
Pulse On X1
16641
CW/CCW
Pulse On X1
3073
Pulse On X2
16645
Pulse On X2
3077
A/B
Quadrature
X1 Leads X2
16642
A/B
Quadrature
X1 Leads X2
3074
X2 Leads X1
16646
X2 Leads X1
3078
200
Step &
Direction
X2 on
12544
1M
Step &
Direction
X2 on
2304
X2 Off
12548
X2 Off
2308
CW/CCW
Pulse On X1
12545
CW/CCW
Pulse On X1
2305
Pulse On X2
12549
Pulse On X2
2309
A/B
Quadrature
X1 Leads X2
12546
A/B
Quadrature
X1 Leads X2
2306
X2 Leads X1
12550
X2 Leads X1
2310
250K
Step &
Direction
X2 on
9984
1.2M
Step &
Direction
X2 on
1792
X2 Off
9988
X2 Off
1796
CW/CCW
Pulse On X1
9985
CW/CCW
Pulse On X1
1793
Pulse On X2
9989
Pulse On X2
1797
A/B
Quadrature
X1 Leads X2
9986
A/B
Quadrature
X1 Leads X2
1794
X2 Leads X1
9990
X2 Leads X1
1798
300K
Step &
Direction
X2 on
8192
1.5M
Step &
Direction
X2 on
1280
X2 Off
8196
X2 Off
1284
CW/CCW
Pulse On X1
8193
CW/CCW
Pulse On X1
1281
Pulse On X2
8197
Pulse On X2
1285
A/B
Quadrature
X1 Leads X2
8194
A/B
Quadrature
X1 Leads X2
1282
X2 Leads X1
8198
X2 Leads X1
1286
400K
Step &
Direction
X2 on
6144
2.0M
Step &
Direction
X2 on
1024
X2 Off
6148
X2 Off
1028
CW/CCW
Pulse On X1
6145
CW/CCW
Pulse On X1
1025
Pulse On X2
6149
Pulse On X2
1029
A/B
Quadrature
X1 Leads X2
6146
A/B
Quadrature
X1 Leads X2
1026
X2 Leads X1
6150
1030