23
920-0084C
8/2/2018
TSM17S/Q Hardware Manual
3.3.7 Programmable Output Y4
TSM17S/Q drives feature one optically isolated digital output Y4. The Y4+(collector) and Y4-
(emitter) terminals of the transistor are available at the connector. This allow the output to be
configured for current sourcing or sinking.
Y4 can be set to provide an output frequency proportional to motor speed (tach signal) or to
provide a timing output (50 pulses/rev) or to indicate whether the motor is in position(static).
Diagrams of various connection types follow.
Do not connect the output to more than 30 volts. The current through the output terminal
must not exceed 100mA.
+
-
Y4+
Y4-
5 - 24
volt DC
Power
Supply
Connecting a Sinking Output
Load
TSM17
COM
IN
Y4+
Y4-
PLC
Connecting a Sourcing Output
5 - 24VDC
Power Supply
TSM17
+
-
+
-
5 - 24
volt DC
Power
Supply
Driving a Relay
Y4+
Y4-
relay
1N4935 suppresion diode
TSM17