background image

3

Power input

Your Omni DMX splitter is equipped with a universal power supply which will 
allow it to operate on input voltages of 

85-250 VAC @ 47-66Hz

.

1 amp 250V fuse

 (3AB 1/4”x1-1/4” style) is provided for protection of internal 

components and should not be replaced with a fuse larger than 1 amp.

The power input connector is a Neutrik 

powerCON

 20A (NAC3MPA-1) and is 

compatible with the NAC3FCA cable mount plug.

The loop-thru 

powerCON

 connector is an NAC3MPB-1 and and is compatible 

with the NAC3FCB cable mount plug.

The loop-thru connection is limited to 10A

. Do not connect more than 10A of 

load current to this outlet as it may cause damage to the unit.

Each splitter comes with a 3' 

powerCON

 to NEMA 5-15 (Edison) input power 

cable.

1' 

powerCON

 A-B jumper cables may be purchased separately to interconnect 

multiple units.

Data input

XLR input and loop-out data connectors are provided for feeding DMX data into 
the Omni splitter and connecting other devices to the same DMX line.

The loop-out connector passes all 5 pins directly and is not isolated from the 
input.

Omni DMX Splitter V1.01 1/31/19

Input connectors, status LEDs & terminator switch

Power input, loop-thru & fuse connections

Summary of Contents for Omni 1x10

Page 1: ...1 Omni DMX Splitter User Manual Omni 1x5 1x10 2x5 Applied Electronics 722 Bluecrab Rd Newport News VA 23606 800 883 0008 appliednn com Omni DMX Splitter V1 01 1 31 19 ...

Page 2: ...lines in excess of 1000ft are not recommended Interference Outside electromagnetic sources can corrupt the data on a DMX line and cause undesired operation of lighting fixtures Surges Voltage spikes from shorted cables and faulty fixtures can feed down the data chain and damage other fixtures or the console The Omni splitter helps eliminate all of these issues by Isolation Each output transmits it...

Page 3: ...he NAC3FCB cable mount plug The loop thru connection is limited to 10A Do not connect more than 10A of load current to this outlet as it may cause damage to the unit Each splitter comes with a 3 powerCON to NEMA 5 15 Edison input power cable 1 powerCON A B jumper cables may be purchased separately to interconnect multiple units Data input XLR input and loop out data connectors are provided for fee...

Page 4: ...nated Data output XLR output data connectors are provided for feeding DMX to up to 32 receivers each The power supply for each output is galvanically isolated from the input and the other outputs The data line of each output are optically isolated from the input and the other outputs Maintenance No routine maintenance procedures are required as your Omni DMX splitter is a solid state device that s...

Page 5: ...LED No power supplied to unit Check the source power outlet and the power supply cable Confirm that the powerCON connector is twisted into the locked position Input power fuse blown Remove fuse turn and check If blown replace with MAX 1A 250V fuse No signal LED and no DMX from loop out port No data being received from transmitter console Test data line with device No signal LED but good DMX confir...

Page 6: ...that the dimple signifying the pin 1 end of the chip is at the same end as the notch in the socket right hand end as pictured 6 Gently press the spare chip until it seats fully in the socket being careful not to bend any leads 7 Replace the top cover 8 Re test the unit for correct operation If after following the trouble shooting guide you believe it necessary to replace the output RS 485 and or o...

Page 7: ...re chip until it seats fully in the socket being careful not to bend any leads 7 Replace the top cover 8 Re test the unit for correct operation Technical Details Omni DMX Splitter V1 01 1 31 19 System Block Diagram Output PCB ...

Page 8: ... 5000VAC per output circuit Voltage suppression 5 8V 57A 330W Dimensions 1 rack space chassis 19 x5 x1 75 Weight 4lb 4oz 4lb 6oz 4lb 8oz Power cable provided 3 18 awg NEMA5 15 Edison to Neutrik NAC3FCA powerCON XLR connectors 5 pin signal list 1 Signal Common cable shield not chassis ground connected to isolated ground of 5VDC power for each outlet i e each signal common is independent 2 Data or B...

Page 9: ...s the right to inspect product for damage not covered under this guarantee before conducting repairs The customer is responsible for shipping product to Applied for service If repaired under warranty product return shipping will be paid by Applied Items repaired or replaced under warranty do not extend or renew the original guarantee period Except as expressly stated and warranted herein i Applied...