2.3
ALARM
In/Out
ALARM1 IN
ALARM4 IN
ALARM2 IN
ALARM3 IN
ALARM OUT
RECORD IN
GROUND
DISK FULL
ALARM RESET
1
2
3
4
5
6
7
8
9
THIS FIGURE IS LOOKED FROM THE REAR VIEW
1. GND:
Ground Contact.
2. ALARM
OUT
(OUTPUT):
This is an alarm output trigger. Connect this to external devices such
as buzzers or lights. (
5V
0V(Active)
)
3.
DISK FULL (OUTPUT):
This is a disk full output trigger. Connect this to external devices such
as buzzers or lights. (
5V
0V(Active)
)
4. ALARM RESET (INPUT):
This pin connects to an alarm-clear device for clearing an alarm.
(
5V
0V(Active)
)
5. RECORD IN (INPUT):
This pin connects to a record trigger device for starting a record.
(
5V
0V(Active)
)
6. ALARM4
IN
(INPUT):
This is an alarm input( for CH 4 )which can be programmed in the menu
system to Normally Open or Normally Closed. (
5V
0V(Active)
)
7.
ALARM3 IN (INPUT):
same as the above, for CH 3
8.
ALARM2 IN (INPUT):
same as the above, for CH 2
9.
ALARM1 IN (INPUT):
same as the above, for CH 1
9