40
(1) Channel Select:
Please select one channel between
Ch1
and
Ch4
.
(2) Type:
An alarm is triggered when the sensor is touched. (
N.C
&
N.O
: Normally Closed / Normally Open).
(3) Sensitivity:
The alarm input in each channel can be set to a sensitivity between
0.1
to
0.8
seconds.
(4) Copy To:
You can also copy the current setting to
All
the cameras or another single camera between
Ch1
and
Ch4
.
5. Alarm
Input
Link:
Select a camera to activate or deactivate the three modes of "
Motion
", “
Sensor
” and "
V
(video)
-Loss
".
(1) Motion:
Alarms which are activated while the motion detection function is operating. Activate
(ON) or
deactivate
□
(OFF).
(2) Sensor:
The alarm input in each channel can be set to a
sensitivity
between
0.1
to
0.8
seconds.
(3) V-Loss:
An alarm occurs when video is lost. Activate
(ON) or deactivate
□
(OFF).
6. Alarm Out Link: